Literature DB >> 9778841

Desktop X-ray microscopy and microtomography.

A Sasov1, D Van Dyck.   

Abstract

Recent developments in X-ray microtomography have made it possible to miniaturize a CT scanner into a versatile and cost-effective desktop system that fits into any laboratory environment. The possibilities of the technique are demonstrated for a range of applications. It is also shown how an existing scanning electron microscope with an X-ray detector can, with a specially developed attachment, be transformed into an X-ray microscope and microtomograph.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9778841

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  9 in total

1.  Optimal sample volumes of human trabecular bone in μCT analysis within vertebral body and femoral head.

Authors:  Xin-Xin Wen; Chun-Lin Zong; Chao Xu; Xiang-Yu Ma; Fa-Qi Wang; Ya-Fei Feng; Ya-Bo Yan; Wei Lei
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  Modeling and measurement of the detector presampling MTF of a variable resolution x-ray CT scanner.

Authors:  Roman Melnyk; Frank A DiBianca
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

3.  Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner.

Authors:  W F Decraemer; J J J Dirckx; W R J Funnell
Journal:  J Assoc Res Otolaryngol       Date:  2003-06

Review 4.  New laboratory tools in the assessment of bone quality.

Authors:  D Chappard; M F Baslé; E Legrand; M Audran
Journal:  Osteoporos Int       Date:  2011-02-24       Impact factor: 4.507

5.  X-ray deconvolution microscopy.

Authors:  Sebastian Ehn; Franz Michael Epple; Andreas Fehringer; David Pennicard; Heinz Graafsma; Peter Noël; Franz Pfeiffer
Journal:  Biomed Opt Express       Date:  2016-03-09       Impact factor: 3.732

6.  Micro-computed tomography characterization of tissue engineering scaffolds: effects of pixel size and rotation step.

Authors:  Ibrahim Fatih Cengiz; Joaquim Miguel Oliveira; Rui L Reis
Journal:  J Mater Sci Mater Med       Date:  2017-07-18       Impact factor: 3.896

7.  Analysis of β-tricalcium phosphate granules prepared with different formulations by nano-computed tomography and scanning electron microscopy.

Authors:  Lisa Terranova; Hélène Libouban; Romain Mallet; Daniel Chappard
Journal:  J Artif Organs       Date:  2015-04-22       Impact factor: 1.731

Review 8.  In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science.

Authors:  Sheridan C Mayo; Andrew W Stevenson; Stephen W Wilkins
Journal:  Materials (Basel)       Date:  2012-05-24       Impact factor: 3.623

Review 9.  Mouse embryo phenotyping using X-ray microCT.

Authors:  Stephan Handschuh; Martin Glösmann
Journal:  Front Cell Dev Biol       Date:  2022-09-16
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.