Literature DB >> 9778704

Influence of contact lens material surface characteristics and replacement frequency on protein and lipid deposition.

C Maïssa1, V Franklin, M Guillon, B Tighe.   

Abstract

The aim of the study was to quantify the influence of both contact lens material and replacement frequency on protein and lipid deposition. The following hypotheses were tested: (1) both protein and lipid interaction with contact lenses are material-dependent, and (2) the key factors are the material ionicity for the protein deposition and the material chemical composition for the lipid deposition. Three high water content contact lens materials were tested: netrafilcon A (FDA group II, Gentle Touch), etafilcon A (FDA group IV, Acuvue), and vifilcon A (FDA group IV, Focus). Contact lens spoilation was analyzed using ultraviolet spectroscopy and fluorescence spectrophotometry. The results showed that (1) significantly more proteins were deposited on the ionic materials than on the nonionic materials, and that among the ionic materials, the higher the ionicity, the higher the level of protein deposition; (2) there were significantly more surface proteins on the ionic materials after 3 months than after 1 month of wear, but no difference over time was demonstrated for the nonionic materials; and (3) significantly more lipids were deposited onto the surface of vifilcon A than etafilcon A or netrafilcon A, and the presence of vinylpyrrolidone in the vifilcon A formulation was thought to be the cause of increased deposition. The protein and lipid interactions with contact lenses were found to be material- and time-dependent. Protein attraction was found to be related to the material ionicity. The presence of vinylpyrrolidone was a key factor in the attraction of lipids.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9778704     DOI: 10.1097/00006324-199809000-00026

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

1.  Evaluation of extractants and precipitants in tear film proteomic analyses.

Authors:  Daniel R Powell; Mirunalni Thangavelu; Heather L Chandler; Kelly K Nichols; Jason J Nichols
Journal:  Optom Vis Sci       Date:  2010-11       Impact factor: 1.973

2.  Gelatin-glutaraldehyde cross-linking on silicone rubber to increase endothelial cell adhesion and growth.

Authors:  Hua Ai; David K Mills; Alexander S Jonathan; Steven A Jones
Journal:  In Vitro Cell Dev Biol Anim       Date:  2002-10       Impact factor: 2.723

3.  Influence of Tear Protein Deposition on the Oxygen Permeability of Soft Contact Lenses.

Authors:  Se Eun Lee; So Ra Kim; Mijung Park
Journal:  J Ophthalmol       Date:  2017-02-09       Impact factor: 1.909

4.  Objective Assessment of Ocular Surface Response to Contact Lens Wear in Presbyopic Contact Lens Wearers of Asian Descent.

Authors:  Michel Guillon; Kathy Dumbleton; Panagiotis Theodoratos; Trisha Patel; Tom Karkkainen; Kurt Moody
Journal:  Eye Contact Lens       Date:  2018-05       Impact factor: 2.018

5.  Quantification of individual proteins in silicone hydrogel contact lens deposits.

Authors:  Negar Babaei Omali; Zhenjun Zhao; Hua Zhu; Daniel Tilia; Mark D P Willcox
Journal:  Mol Vis       Date:  2013-02-18       Impact factor: 2.367

6.  Mass spectrometry-based proteomic analyses of contact lens deposition.

Authors:  Kari B Green-Church; Jason J Nichols
Journal:  Mol Vis       Date:  2008-02-08       Impact factor: 2.367

7.  Adhesive capabilities of Staphylococcus aureus and Pseudomonas aeruginosa isolated from tears of HIV/AIDS patients to soft contact lenses.

Authors:  B O Ajayi; F E Kio; F D Otajevwo
Journal:  Glob J Health Sci       Date:  2012-01-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.