Monte Carlo calculation of single-beam dose profiles used in a gamma knife treatment planning system.

J Y Cheung1, K N Yu, C P Yu, R T Ho.   

Abstract

The accuracy of single-beam dose profiles used in the algorithm of the Gamma Knife treatment planning system (Leksell GammaPlan) is verified. EGS4 Monte Carlo calculation was employed to calculate the dose distributions of single-beams in a spherical water phantom with diameter 160 mm. The beams were directed to the center of the phantom. Collimators of 4, 8, 14, and 18 mm sizes were studied. The single-beam dose profiles provided by Elekta (Manufacturer of Leksell Gamma Knife) were excellently consistent with the results of Monte Carlo for the 4, 14, and 18 mm collimators. The maximum discrepancy was less than 3% at all radial distances. For the 8 mm collimator, the maximum discrepancy was 8% in the relative dose in the radial distance range from 4.3 mm to 5.2 mm. Excellent agreement in dose profiles along x, y, and z axes for all collimator helmets by summing over all 201 sources was observed between the cases using the default single-beam dose profiles and the calculated Monte Carlo results, except for the 8 mm collimator helmet along z axis. Such difference may however be too small to give a clinical significance.

Entities:  

Mesh:

Year:  1998        PMID: 9775372     DOI: 10.1118/1.598347

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

Review 1.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

2.  Study of a spherical phantom for Gamma knife dosimetry.

Authors:  Dengsong Zhu; Carlos Austerlitz; Sidi Benhabib; Helvecio Mota; Ron R Allison; Diana Campos
Journal:  J Appl Clin Med Phys       Date:  2010-04-17       Impact factor: 2.102

3.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

4.  Evaluation of dose delivery accuracy of Gamma Knife by polymer gel dosimetry.

Authors:  Yoichi Watanabe; Tomohide Akimitsu; Yutaka Hirokawa; Rob B Mooij; G Mark Perera
Journal:  J Appl Clin Med Phys       Date:  2005-08-12       Impact factor: 2.102

5.  Development of a Monte Carlo model for treatment planning dose verification of the Leksell Gamma Knife Perfexion radiosurgery system.

Authors:  Jiankui Yuan; Simon S Lo; Yiran Zheng; Jason W Sohn; Andrew E Sloan; Rodney Ellis; Mitchell Machtay; Barry Wessels
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102