Literature DB >> 9773958

Comparison of instrument-read dipsticks for albumin and creatinine in urine with visual results and quantitative methods.

M J Pugia1, J A Lott, K E Luke, Z K Shihabi, F H Wians, L Phillips.   

Abstract

Three hospital sites evaluated the Bayer two-pad urine dipstick as a screening test for microalbuminuria. One pad estimates albumin concentrations between 10 and 150 mg/L, and the second estimates creatinine values between 300 and 3,000 mg/L. The Boehringer Mannheim (BMD) Micral dipstick was also compared and evaluated. The accuracy of the dipsticks was judged by comparison with cuvet-based immunonephelometry for albumin and to standard rate-Jaffe methods for creatinine; these assays were well standardized and controlled and were assumed to give accurate values. Precision of these methods and that of the dipsticks was determined by multiple assays of control materials. Visual or instrument (Clinitek 50 or 100) evaluation of the Bayer or visual checks of the BMD albumin dipstick pad with patients' urines gave clinically acceptable accuracy. The albumin/creatinine ratio from the Bayer dipsticks gave better accuracy for albumin excretion than the albumin pads alone from either manufacturer. This ratio should permit making a good estimate of the 24-hr albumin excretion in a randomly collected urine.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9773958      PMCID: PMC6807859          DOI: 10.1002/(sici)1098-2825(1998)12:5<280::aid-jcla5>3.0.co;2-a

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  16 in total

1.  Comparison of urine dipsticks with quantitative methods for microalbuminuria.

Authors:  M J Pugia; J A Lott; L W Clark; D R Parker; J F Wallace; T W Willis
Journal:  Eur J Clin Chem Clin Biochem       Date:  1997-09

2.  Impact of posture on the "reference range" for serum proteins and calcium.

Authors:  K R Humphrey; H D Gruemer; J A Lott
Journal:  Clin Chem       Date:  1977-07       Impact factor: 8.327

Review 3.  Prevention of diabetic renal disease with special reference to microalbuminuria.

Authors:  C E Mogensen; W F Keane; P H Bennett; G Jerums; H H Parving; P Passa; M W Steffes; G E Striker; G C Viberti
Journal:  Lancet       Date:  1995-10-21       Impact factor: 79.321

4.  Clinical significance of microalbuminuria and evaluation of the Micral-Test.

Authors:  C Hasslacher
Journal:  Clin Biochem       Date:  1993-08       Impact factor: 3.281

5.  Use of single voided urine samples to estimate quantitative proteinuria.

Authors:  J M Ginsberg; B S Chang; R A Matarese; S Garella
Journal:  N Engl J Med       Date:  1983-12-22       Impact factor: 91.245

6.  Does microalbuminuria predict cardiovascular events in nondiabetic men with treated hypertension? Risk Factor Intervention Study Group.

Authors:  S Agewall; J Wikstrand; S Ljungman; H Herlitz; B Fagerberg
Journal:  Am J Hypertens       Date:  1995-04       Impact factor: 2.689

7.  Protein creatinine index and Albustix in assessment of proteinuria.

Authors:  A B Shaw; P Risdon; J D Lewis-Jackson
Journal:  Br Med J (Clin Res Ed)       Date:  1983-10-01

Review 8.  Microalbuminuria. Implications for micro- and macrovascular disease.

Authors:  T Deckert; A Kofoed-Enevoldsen; K Nørgaard; K Borch-Johnsen; B Feldt-Rasmussen; T Jensen
Journal:  Diabetes Care       Date:  1992-09       Impact factor: 19.112

9.  Factors related to the presence of microalbuminuria in essential hypertension.

Authors:  J Redon; Y Liao; J V Lozano; A Miralles; E Baldo; R S Cooper
Journal:  Am J Hypertens       Date:  1994-09       Impact factor: 2.689

10.  Diurnal variations of blood pressure and microalbuminuria in essential hypertension.

Authors:  S Bianchi; R Bigazzi; G Baldari; G Sgherri; V M Campese
Journal:  Am J Hypertens       Date:  1994-01       Impact factor: 2.689

View more
  5 in total

1.  Using protein/creatinine ratios in random urine.

Authors:  Mitsuhiro Watanabe; Kazuhiko Funabiki; Toshinao Tsuge; Kunimi Maeda; Satoshi Horikoshi; Yasuhiko Tomino
Journal:  J Clin Lab Anal       Date:  2005       Impact factor: 2.352

Review 2.  Urinary strips for protein assays: easy to do but difficult to interpret!

Authors:  Guillaume Résimont; Laurence Piéroni; Edith Bigot-Corbel; Etienne Cavalier; Pierre Delanaye
Journal:  J Nephrol       Date:  2020-04-23       Impact factor: 3.902

3.  Measurement of the albumin content of urinary protein using dipsticks.

Authors:  M Sasaki; M J Pugia; D R Parker; K Kuromoto; I Furukawa; I Konishi
Journal:  J Clin Lab Anal       Date:  1999       Impact factor: 2.352

4.  Albuminuria and proteinuria in hospitalized patients as measured by quantitative and dipstick methods.

Authors:  M J Pugia; J F Wallace; J A Lott; R Sommer; K E Luke; Z K Shihabi; M Sheehan; J M Bucksa
Journal:  J Clin Lab Anal       Date:  2001       Impact factor: 2.352

5.  High-sensitivity dye binding assay for albumin in urine.

Authors:  M J Pugia; J A Lott; J A Profitt; T K Cast
Journal:  J Clin Lab Anal       Date:  1999       Impact factor: 2.352

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.