Literature DB >> 9773829

The reduction half cell in biomaterials corrosion: oxygen diffusion profiles near and cell response to polarized titanium surfaces.

J L Gilbert1, L Zarka, E Chang, C H Thomas.   

Abstract

Mechanically assisted corrosion processes can greatly increase the oxidation currents generated in passivating alloy systems like Co-Cr and titanium due to oxide film disruption. When oxide films are abraded, repassivation and ionic dissolution both occur at rates that are orders of magnitude higher than undisrupted surfaces. The excess electrons generated by these anodic processes must be consumed in corresponding reduction reactions that include the reduction of oxygen. If large enough, these reduction reactions may locally deplete the concentration of solution-dissolved oxygen and, in turn, affect cell behavior in the vicinity of the implant surface. To date, this hypothesis has not been tested. In the present study, a scanning electrochemical microscope was used to measure oxygen concentration profiles in vitro near a planar titanium electrode polarized to different voltages representative of those attainable by titanium undergoing mechanically assisted corrosion. The potentials investigated ranged from 0 mV to -1000 mV (AgCl). The oxygen concentration as a function of distance from the titanium surface was measured using a platinum-iridium microelectrode and an amperometric technique. Also, preliminary experiments were performed to assess the response of rat calvarial osteoblast-rich cells cultured for 2 h on titanium samples polarized to two different potentials (0 mV and -1000 mV versus AgCl). The results of this study indicate that oxygen concentrations near titanium surfaces are affected by sample potentials out to probe-sample distances as great as 500 microm. Within 2 microm of the surface, oxygen concentrations decreased by 15 to 25% for sample potentials between -100 and -500 mV. At potentials more negative than -600 mV, the oxygen concentration dropped rapidly to near zero by -900 mV. The cell experiments showed a statistically significant difference in the amount of cell spreading, as measured by projected cell area, between the two groups (p < 0.03), with the cells cultured at -1000 mV undergoing much less spreading. This implies that -1000 mV inhibits normal cell behavior at the titanium surface and that this is most likely due, at least in part, to a diminished oxygen supply.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9773829     DOI: 10.1002/(sici)1097-4636(199811)42:2<321::aid-jbm18>3.0.co;2-l

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

1.  Electrochemical properties of 316L stainless steel with culturing L929 fibroblasts.

Authors:  Sachiko Hiromoto; Takao Hanawa
Journal:  J R Soc Interface       Date:  2006-08-22       Impact factor: 4.118

2.  Electrical polarization of titanium surfaces for the enhancement of osteoblast differentiation.

Authors:  Rolando A Gittens; Rene Olivares-Navarrete; Robert Rettew; Robert J Butera; Faisal M Alamgir; Barbara D Boyan; Zvi Schwartz
Journal:  Bioelectromagnetics       Date:  2013-08-29       Impact factor: 2.010

3.  In vitro assessment of serum-saline ratios for fluid simulator testing of highly modular spinal implants with articulating surfaces.

Authors:  Nadim Hallab; Ashutosh Khandha; George Malcolmson; J P Timm
Journal:  SAS J       Date:  2008-12-01

4.  Surface micro- and nano-texturing of stainless steel by femtosecond laser for the control of cell migration.

Authors:  M Martínez-Calderon; M Manso-Silván; A Rodríguez; M Gómez-Aranzadi; J P García-Ruiz; S M Olaizola; R J Martín-Palma
Journal:  Sci Rep       Date:  2016-11-02       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.