T Y Ma1, R Yoshinaka, A Banaag, B Johnson, S Davis, S M Berman.
Abstract
The purpose of this study was to determine in a randomized, prospective manner whether administration of total parenteral nutrition (TPN) via multilumen catheters increases the risk of catheter-related sepsis (CRS). All patients receiving hyperalimentation during a 24-month period were randomized to receive either a double-lumen catheter (DLC) or a triple-lumen catheter (TLC). A total of 101 catheters were placed in 79 patients, of which 49 were DLCs and 52 were TLCs. The patients with DLCs received a total of 784 days of TPN, whereas patients with TLCs received a total of 754 days of TPN. CRS was associated with one (2.0%) of the 49 DLCs vs. one (1.9%) of the 52 TLCs. In comparison, the rate of CRS associated with single-lumen catheters (historical control) at our institution was 1.4% (P > .90). We conclude that the use of multilumen catheters in TPN therapy does not result in an increased risk of CRS.Entities:
Mesh:
Year: 1998 PMID: 9770147 DOI: 10.1086/514687