G D Williams1, S L Bratton, E C Riley, C Ramamoorthy. 1. Department of Anesthesiology, Children's Hospital and Regional Medical Center, University of Washington School of Medicine, Seattle 98105-0371, USA. jwilli@chmc.org
Abstract
BACKGROUND: Although recent studies indicated young children are at risk for increased perioperative hemorrhage after open heart operations, the associations between patient age, blood loss and blood product transfusions have not been fully defined in children. METHODS: Perioperative blood loss and blood product transfusion data were recorded for 414 consecutive children undergoing open heart procedures. The children were in the following age groups: 1 month or younger, group 1; older than 1 month to 12 months, group 2; older than 1 year to 5 years, group 3; and older than 5 years, group 4. RESULTS: Postoperative blood loss and blood product transfusions were inversely related to age and differed significantly between the four age groups. Multiple preoperative and intraoperative factors that possibly influence hemostasis also differed significantly between age groups. Median units transfused within 72 hours differed significantly with age (p < 0.0001): group 1, 8 units (range, 1 to 19 units); group 2, 6 units (range, 0 to 21 units); group 3, 2 units (range, 0 to 23 units); and group 4, 0 units (range, 0 to 38 units). CONCLUSIONS: Blood loss and transfusions vary inversely with age. Per kilogram of body weight, neonates bled more and received more donor products than any other age group.
BACKGROUND: Although recent studies indicated young children are at risk for increased perioperative hemorrhage after open heart operations, the associations between patient age, blood loss and blood product transfusions have not been fully defined in children. METHODS: Perioperative blood loss and blood product transfusion data were recorded for 414 consecutive children undergoing open heart procedures. The children were in the following age groups: 1 month or younger, group 1; older than 1 month to 12 months, group 2; older than 1 year to 5 years, group 3; and older than 5 years, group 4. RESULTS:Postoperative blood loss and blood product transfusions were inversely related to age and differed significantly between the four age groups. Multiple preoperative and intraoperative factors that possibly influence hemostasis also differed significantly between age groups. Median units transfused within 72 hours differed significantly with age (p < 0.0001): group 1, 8 units (range, 1 to 19 units); group 2, 6 units (range, 0 to 21 units); group 3, 2 units (range, 0 to 23 units); and group 4, 0 units (range, 0 to 38 units). CONCLUSIONS:Blood loss and transfusions vary inversely with age. Per kilogram of body weight, neonates bled more and received more donor products than any other age group.
Authors: Colleen E Gruenwald; Cedric Manlhiot; Lynn Crawford-Lean; Celeste Foreman; Leonardo R Brandão; Brian W McCrindle; Helen Holtby; Ross Richards; Helen Moriarty; Glen Van Arsdell; Anthony K Chan Journal: J Extra Corpor Technol Date: 2010-03
Authors: Hemant S Agarwal; Sarah S Barrett; Kristen Barry; Meng Xu; Benjamin R Saville; Brian S Donahue; Zena L Harris; David P Bichell Journal: Pediatr Cardiol Date: 2014-10-08 Impact factor: 1.655
Authors: Jill M Cholette; Jennifer A Muszynski; Juan C Ibla; Sitaram Emani; Marie E Steiner; Adam M Vogel; Robert I Parker; Marianne E Nellis; Melania M Bembea Journal: Pediatr Crit Care Med Date: 2022-01-01 Impact factor: 3.971
Authors: Nicole M J Zwifelhofer; Rachel S Bercovitz; Regina Cole; Ke Yan; Pippa M Simpson; Alyssa Moroi; Peter J Newman; Robert A Niebler; John P Scott; Eckehard A D Stuth; Ronald K Woods; D Woodrow Benson; Debra K Newman Journal: Thromb Haemost Date: 2019-11-21 Impact factor: 5.249
Authors: Michelle K Brenner; Shanelle Clarke; Donna K Mahnke; Pippa Simpson; Rachel S Bercovitz; Aoy Tomita-Mitchell; Michael E Mitchell; Debra K Newman Journal: Pediatr Res Date: 2015-10-22 Impact factor: 3.756
Authors: Jong Wha Lee; Young-Chul Yoo; Han Ki Park; Sou-Ouk Bang; Ki-Young Lee; Sun-Joon Bai Journal: Yonsei Med J Date: 2013-05-01 Impact factor: 2.759