Literature DB >> 9768732

Cardiac death and stored electrograms in patients with third-generation implantable cardioverter-defibrillators.

E M Grubman1, B B Pavri, T Shipman, N Britton, D Z Kocovic.   

Abstract

OBJECTIVES: We sought to utilize terminal stored intracardiac electrograms (EGMs) to study the electrophysiologic events that accompany mortality in patients with third-generation implantable cardioverter-defibrillators (ICDs).
BACKGROUND: Despite their ability to effectively terminate ventricular tachyarrhythmias, cardiac mortality in patients with ICDs remains high. The mechanisms and modes of death in these patients are not well understood.
METHODS: We retrospectively analyzed clinical data and stored EGMs from patients enrolled in the clinical trial of the Ventritex Cadence ICD. Of the 1,729 patients 119 died during 6 years of follow-up. The final recorded EGM was reviewed. Postimplant EGMs as well as 50 control EGMs were used to define normal EGM characteristics.
RESULTS: There were 36 noncardiac deaths (30%) and 83 cardiac deaths (70%). Of the cardiac deaths, 55 (66%) were nonsudden and 28 (34%) were sudden. When cardiac deaths were analyzed, 46 (55%) had no stored EGMs within 1 h of death, implying that the deaths were not directly related to tachyarrhythmias. In 37 cardiac deaths (18 nonsudden, 19 sudden), stored EGMs were present within 1 h of death. In these 37 deaths, the final EGM recorded was wide (>158 ms) in 33 (89%). Wide EGMs were interpreted as ventricular tachycardia in 27 and ventricular fibrillation in 6. In 13 of the 33 patients (39%) with wide EGMs, therapy was not delivered by the ICD, as it incorrectly detected a spontaneous termination of the arrhythmia. EGMs were significantly wider if recorded within 1 h, as compared with those recorded from 1 to 48 h before death (261+/-124 vs. 181+/-93 ms, p=0.04).
CONCLUSIONS: Only 37 patients (31%) who died after placement of an ICD had a stored EGM within 1 h of the time of death, suggesting that the majority of deaths (69%) were not the immediate result of a tachyarrhythmia. When EGMs were recorded, they were wide in 89% of patients. These wide EGMs most likely represent intracardiac recordings of electromechanical dissociation. Thus, of the 119 deaths, 112 (94%) were not the immediate result of a tachyarrhythmia.

Entities:  

Mesh:

Year:  1998        PMID: 9768732     DOI: 10.1016/s0735-1097(98)00359-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

1.  The history, science, and innovation of Holter technology.

Authors:  Harold L Kennedy
Journal:  Ann Noninvasive Electrocardiol       Date:  2006-01       Impact factor: 1.468

Review 2.  Do arrhythmias still deserve our intellectual efforts?: The 2002 Wenckebach Lecture of the Netherlands Society of Cardiology.

Authors:  N M van Hemel
Journal:  Neth Heart J       Date:  2003-08       Impact factor: 2.380

Review 3.  Out-of-hospital cardiac arrest -optimal management.

Authors:  Georg M Fröhlich; Richard M Lyon; Comilla Sasson; Tom Crake; Mark Whitbread; Andreas Indermuehle; Adam Timmis; Pascal Meier
Journal:  Curr Cardiol Rev       Date:  2013-11

Review 4.  The incidence and impact of implantable cardioverter defibrillator shocks in the last phase of life: An integrated review.

Authors:  Rik Stoevelaar; Arianne Brinkman-Stoppelenburg; Rohit E Bhagwandien; Rozemarijn L van Bruchem-Visser; Dominic Amj Theuns; Agnes van der Heide; Judith Ac Rietjens
Journal:  Eur J Cardiovasc Nurs       Date:  2018-05-18       Impact factor: 3.908

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.