Nerve regeneration over a 20-mm gap through a nerve conduit containing blood vessels in rats: the influence of interstump distance on nerve regeneration.

R Kakinoki1, N Nishijima, Y Ueba, M Oka, T Yamamuro, T Nakamura.   

Abstract

BACKGROUND: The present study was conducted in rats to investigate whether a tube with additional intrachamber vascularization could permit axons to extend over a distance greater than 10 mm, which appears to be the maximum axon regeneration distance for rat sciatic nerve axons through a normal empty tube.
METHODS: A sural vessel-containing tube (VCT) was designed and interposed between transected sciatic nerve stumps in the thigh, leaving a 20-mm interneural gap.
RESULTS: Twelve weeks after tubulation, six out of nine rats showed successful nerve regeneration and re-innervation of the soleus muscle using the VCT. At 24 weeks, intrachamber nerve regeneration and re-innervation of the soleus and pedal adductor muscles were electrophysiologically and histologically confirmed in all rats. However, no neural tissue was observed within any ligated sural vessel-containing tube (LVCT) or empty unmodified tube (ET) with a 20-mm interneural gap. When nerves regenerated in the VCT with a 20-mm gap were compared with those regenerated in a VCT with a 10-mm gap 12 and 24 weeks after surgery, the results produced by the VCT with a 20-mm gap were inferior to those after use of the VCT with a 10-mm gap, except for motor nerve conduction velocity at 24 weeks.
CONCLUSIONS: The value recovered to almost identical levels (about 50-60% normal) in both groups.

Entities:  

Mesh:

Year:  1998        PMID: 9766268

Source DB:  PubMed          Journal:  J Neurosurg Sci        ISSN: 0390-5616            Impact factor:   2.279


  3 in total

Review 1.  Machine intelligence for nerve conduit design and production.

Authors:  Caleb E Stewart; Chin Fung Kelvin Kan; Brody R Stewart; Henry W Sanicola; Jangwook P Jung; Olawale A R Sulaiman; Dadong Wang
Journal:  J Biol Eng       Date:  2020-09-09       Impact factor: 4.355

Review 2.  3D Printed Personalized Nerve Guide Conduits for Precision Repair of Peripheral Nerve Defects.

Authors:  Kai Liu; Lesan Yan; Ruotao Li; Zhiming Song; Jianxun Ding; Bin Liu; Xuesi Chen
Journal:  Adv Sci (Weinh)       Date:  2022-02-18       Impact factor: 17.521

3.  Effect of Artificial Nerve Conduit Vascularization on Peripheral Nerve in a Necrotic Bed.

Authors:  Yuki Iijima; Takashi Ajiki; Akira Murayama; Katsushi Takeshita
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-03-22
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.