Literature DB >> 9765688

[Remarks on the dosage problem in HDR brachytherapy].

P Kneschaurek1.   

Abstract

BACKGROUND: In HDR brachytherapy activity distributions can be achieved which were unknown in LDR brachytherapy. For this reason the classical dosage systems can only be used with caution in HDR brachytherapy.
METHODS: Different simple applications are used to investigate the effect of various activity distributions on dose and integrated reference air kerma.
RESULTS: Within the classical LDR dosage systems dose and integrated reference air kerma were equivalent. Due to the possibility to "optimize" the activity distribution in HDR brachytherapy this is not longer the case. Different optimization algorithms and different optimization goals may lead to quite different activity distributions and different integrated reference air kerma values even if the source positions are the same. For target volume oriented optimization schemes a dosage system is described which is based on dose-volume-histograms.
CONCLUSIONS: A widely accepted dosage system in HDR brachytherapy is missing. The dosage system described in this paper may be useful in solving this problem.

Mesh:

Year:  1998        PMID: 9765688     DOI: 10.1007/bf03038625

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  6 in total

1.  REMOTE AFTERLOADING WITH INTRACAVITARY APPLICATORS.

Authors:  U K HENSCHKE; B S HILARIS; G D MAHAN
Journal:  Radiology       Date:  1964-08       Impact factor: 11.105

2.  A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy.

Authors:  D Baltas; C Kolotas; K Geramani; R F Mould; G Ioannidis; M Kekchidi; N Zamboglou
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-01-15       Impact factor: 7.038

3.  A system for nonradiographic source localization and real-time planning of intraoperative high dose rate brachytherapy.

Authors:  Y Watanabe; L L Anderson
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

Review 4.  [A proposal for dosage and volume specification and documentation in HDR brachytherapy].

Authors:  H Krieger; D Baltas; P Kneschaurek
Journal:  Strahlenther Onkol       Date:  1996-10       Impact factor: 3.621

5.  The evaluation of optimized implants for idealized implant geometries.

Authors:  D A Low; J F Williamson
Journal:  Med Phys       Date:  1995-09       Impact factor: 4.071

6.  The Paris system in interstitial radiation therapy.

Authors:  B Pierquin; A Dutreix; C H Paine; D Chassagne; G Marinello; D Ash
Journal:  Acta Radiol Oncol Radiat Phys Biol       Date:  1978
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.