Literature DB >> 9764494

Coupling on-line brain microdialysis, precolumn derivatization and capillary electrophoresis for routine minute sampling of O-phosphoethanolamine and excitatory amino acids.

F Robert1, L Bert, S Parrot, L Denoroy, L Stoppini, B Renaud.   

Abstract

In previous papers, we described the analysis of excitatory amino acids (EAAs) and catecholamines in microdialysis samples using capillary electrophoresis with laser-induced fluorescence detection (CE-LIFD). In the present paper, we report that an automated analysis of such samples can be easily achieved by on-line coupling of the microdialysis probe with a continuous flow derivatization system and a commercially available CE-LIFD apparatus. Because of the short analysis time (less than 2 min) and high separation efficiency (100-200,000 theoretical plates), high temporal resolution of microdialysis (minute range) is preserved as compared to off-line systems, while both EAAs and O-phosphoethanolamine (PEA) can be simultaneously detected. This new method has been applied to the measurement of these compounds in microdialysis samples from hippocampal slice cultures and striatum of anesthetized rats. Extracellular concentrations of EAAs, but not PEA, increased during perfusion of a solution containing high K+ or a glutamate uptake inhibitor. However, after in vitro ischemia on hippocampal slices, both EAAs and PEA concentrations increased, but with different temporal patterns.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9764494     DOI: 10.1016/s0021-9673(98)00321-5

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Microperfusion of 3-MPA into the brain augments GABA.

Authors:  Andrew P Mayer; Ivan Osorio; Craig E Lunte
Journal:  Epilepsy Behav       Date:  2013-10-02       Impact factor: 2.937

2.  Correlation of 3-mercaptopropionic acid induced seizures and changes in striatal neurotransmitters monitored by microdialysis.

Authors:  Eric W Crick; Ivan Osorio; Mark Frei; Andrew P Mayer; Craig E Lunte
Journal:  Eur J Pharm Sci       Date:  2014-01-22       Impact factor: 4.384

3.  High temporal resolution of amino acid levels in rat nucleus accumbens during operant ethanol self-administration: involvement of elevated glycine in anticipation.

Authors:  Zhimin Li; Aleutina Zharikova; Jaime Bastian; Leonardo Esperon; Nicole Hebert; Clare Mathes; Neil E Rowland; Joanna Peris
Journal:  J Neurochem       Date:  2008-07-01       Impact factor: 5.372

4.  Detection and quantification of neurotransmitters in dialysates.

Authors:  Agustin Zapata; Vladimir I Chefer; Toni S Shippenberg; Luc Denoroy
Journal:  Curr Protoc Neurosci       Date:  2009-07

Review 5.  Recent trends in microdialysis sampling integrated with conventional and microanalytical systems for monitoring biological events: a review.

Authors:  Pradyot Nandi; Susan M Lunte
Journal:  Anal Chim Acta       Date:  2009-08-03       Impact factor: 6.558

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.