Literature DB >> 9763387

Integral and shell-MIP display algorithms in MR and CT three-dimensional models of the brain surface.

S O Casey1, D Rubinstein, K O Lillehei, R A Alberico, R R Ozsvath, A G Cajade-Law, B E Weprin, E Michel, C L Truwit.   

Abstract

BACKGROUND AND
PURPOSE: Our purpose was to demonstrate the use of integral and shell maximum intensity projection (shell-MIP) display algorithms in the 3-D CT and MR depiction of cerebral gyral and surface venous anatomy and disorders. These new algorithms are compared against MIP and shaded-surface-display (SSD) algorithms.
METHODS: Integral and shell-MIP displays were generated from a specified number of proximal surface voxel layers in a 3-D model. Algorithmic models were compared on nine contrast-enhanced spoiled gradient-recalled acquisition in a steady state (SPGR) MR venograms for brain surface anatomic identification and detail. Seven CT venograms were compared for conspicuity of filling defects. Twelve contrast-enhanced preoperative planning 3-D MR models were rated for neurosurgical utility.
RESULTS: A shell-MIP score of 7.00 and an integral score of 6.78 represented the highest mean subjective MR gyral quality (1-10 scale) followed by an SSD score of 3.89 and an MIP score of 1.06. Mean confidence scores for MR central sulcus identification (1-10 scale) were shell-MIP, 7.67; integral, 7.00; SSD, 3.22; and MIP, 1.00. Mean superficial venous quality MR ratings (1-10 scale) were shell-MIP, 8.22; MIP, 7.39; integral, 7.00; and SSD, 3.72. The mean number of cortical veins draining into each side of the superior sagittal sinus on MR was as follows: MIP, 6.19; integral, 6.06; shell-MIP, 5.94; and SSD, 3.81. Mean confidence scores for filling defect identification on CT venograms (1-5 scale) revealed a shell-MIP score of 4.36 and an integral score of 4.29 to be superior to a MIP score of 3.00. In selected cases, 3-D presurgical planning, prior to tumor resection, was clinically useful.
CONCLUSION: Integral and shell-MIP are useful 3-D display algorithms for simultaneous display of superficial cerebral veins and gyri on MR images and of thrombosis on CT venograms.

Entities:  

Mesh:

Year:  1998        PMID: 9763387      PMCID: PMC8338673     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  2 in total

1.  Importance of Veins for Neurosurgery as Landmarks Against Brain Shifting Phenomenon: An Anatomical and 3D-MPRAGE MR Reconstruction of Superficial Cortical Veins.

Authors:  Santino Ottavio Tomasi; Giuseppe Emmanuele Umana; Gianluca Scalia; Roberto Luis Rubio-Rodriguez; Pier Francesco Cappai; Crescenzo Capone; Giuseppe Raudino; Bipin Chaurasia; Maurizio Salvati; Nicolas Jorden; Peter A Winkler
Journal:  Front Neuroanat       Date:  2020-12-15       Impact factor: 3.856

2.  The Use of Osirix for Surgical Planning Using Cranial Measures and Region of Interest Tools: Technical Note.

Authors:  Renan Maximilian Lovato; Joao Luiz Vitorino Araujo; Aline Lariessy Campos Paiva; Francisco Spessatto Pesente; Cumhur Kaan Yaltirik; Mehmet Volkan Harput; José Carlos Esteves Veiga
Journal:  Asian J Neurosurg       Date:  2019 Jul-Sep
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.