Literature DB >> 9763172

Delayed aseptic swelling after fixation of talar neck fracture with a biodegradable poly-L-lactide rod: case reports.

N Yoshino1, S Takai, Y Watanabe, K Kamata, Y Hirasawa.   

Abstract

A 63-year-old woman complained of acute swelling and pain in her ankle at 15 months, after fixation of a talar neck fracture with poly-L-lactide rods. Roentgenographic and laboratory data revealed no abnormalities, but T1-weighted magnetic resonance imaging showed a diffuse area of low intensity in the talus. After nonweightbearing for 1 month, local findings had disappeared and the area of low intensity shown by magnetic resonance imaging had decreased without surgical treatment. Although there have been some reports of aseptic swelling or synovitis after fixation of a fracture with polyglycolide rods or screws, there has been no report of such cases with poly-L-lactide rods or screws.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9763172     DOI: 10.1177/107110079801900913

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  1 in total

1.  The response of macrophages to particles of resorbable polymers and their degradation products.

Authors:  E N Dawes; S A Clarke; N Lamanuzzi; E Pinto; R A Brooks; N Rushton
Journal:  J Mater Sci Mater Med       Date:  2003-03       Impact factor: 3.896

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.