Literature DB >> 975977

A comparison of two bipolar exercise electrocardiographic leads to lead V5.

V F Froelicher, R Wolthius, N Keiser, A Stewart, J Fischer, M R Longo, J H Triebwasser, M C Lancaster.   

Abstract

ST-segment depression and slope were compared in three lead systems (V5, CC5, and CM5) and in two groups of patients using both visual analysis of electrocardiographic paper and computerized techniques. Bipolar lead CC5 was found to be comparable to lead V5 when visual analysis of electrocardiographic recordings was utilized. Bipolar lead CM5 was found not to be comparable to lead V5 and to be less sensitive if classic criteria for slope were used. The technique of computerized analysis mad measurements of slope and amplitude to a reproducible level not possible with the standard technique. Statistically significant differences were found between the exercise electrocardiographic leads utilizing computerized electrocardiographic analysis . We conclude that computerized techniques of electrocardiographic analysis require new criteria for defining an abnormal repolarization response. The criteria must be specific for different electrocardiographic leads if the repolarization changes in these leads are to have comparable diagnostic significance.

Entities:  

Mesh:

Year:  1976        PMID: 975977     DOI: 10.1378/chest.70.5.611

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  8 in total

Review 1.  Intraoperative automated ST segment analysis: a reliable 'black box'?

Authors:  H Yang
Journal:  Can J Anaesth       Date:  1996-10       Impact factor: 5.063

2.  Value of the bipolar lead CM5 in electrocardiography.

Authors:  A A Quyyumi; T Crake; L J Mockus; C A Wright; A F Rickards; K M Fox
Journal:  Br Heart J       Date:  1986-10

3.  Simplified electrode array for impedance cardiography.

Authors:  B C Penney; N A Patwardhan; H B Wheeler
Journal:  Med Biol Eng Comput       Date:  1985-01       Impact factor: 2.602

4.  Evaluation and management of the cardiac patient for office oral surgery.

Authors:  C Niebergall; J A Giglio; R L Campbell
Journal:  Anesth Prog       Date:  1983 May-Jun

5.  Diagnostic value of routine exercise testing in hospital patients with angina pectoris.

Authors:  J A Raffo; I Y Luksic; C T Kappagoda; D A Mary; J B Stoker; W Whitaker; R J Linden
Journal:  Br Med J       Date:  1979-08-04

Review 6.  Anaesthesia for abdominal aortic surgery--a review (Part II).

Authors:  A J Cunningham
Journal:  Can J Anaesth       Date:  1989-09       Impact factor: 5.063

7.  Hemodynamic monitoring and care of the patient of high risk for anesthesia.

Authors:  S P Pietak; S J Teasdale
Journal:  Can Med Assoc J       Date:  1979-10-06       Impact factor: 8.262

8.  Beat-ID: Towards a computationally low-cost single heartbeat biometric identity check system based on electrocardiogram wave morphology.

Authors:  Joana S Paiva; Duarte Dias; João P S Cunha
Journal:  PLoS One       Date:  2017-07-18       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.