Literature DB >> 9757376

[Pseudoaneurysm in the vicinity of the ascending aorta caused by contained disruption at the insertion site of a coronary artery bypass graft. A case report].

A Drögemüller1, R Zahn, C Bergmeier, C Werling, F Isgro, J Senges.   

Abstract

In this case report a 65-year-old patient came into the emergency ward with acute chest pain after coronary artery bypass graft operation in 1985. On routine chest X-ray in 1995 a mediastinal widening was diagnosed. The chest X-ray in 1997 (Figure 1) showed an increase of the diameter of the known mediastinal widening. Therefore a CT-scan was performed (Figures 2a and 2b). This showed an enhancement of contrast material in a contained structure, without identifying its origin. Therefore a coronary angiography was done. Here, we diagnosed a contained disruption of the aorta at the insertion site of the bypass graft at the right coronary artery. Figure 3a shows leakage of contrast material out of the aorta into the pseudoaneurysm and in Figure 3b this is demonstrated in a schematic drawing. Figure 4a shows supraselective imaging of the pseudoaneurysm, demonstrated in a schematic drawing in Figure 4b. As the chest pain could only be handled by i.v.-medication, betablocker and bed rest we decided to operate. Intra-operatively the diagnosis was confirmed (Figure 5a and 5b). Postoperatively the patient died due to cerebral ischemia. Despite the lethal outcome an operative revision appears even retrospectively justified because of the increasing size of the pseudoaneurysm in addition to new symptoms that were difficult to treat. On the other hand there are no data available in order to estimate the risk of a spontaneous course.

Entities:  

Mesh:

Year:  1998        PMID: 9757376     DOI: 10.1007/bf03044360

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  10 in total

1.  Bronchial obstruction secondary to aortic pseudoaneurysm: treatment with an expandable metallic stent.

Authors:  J P Weiss; W P Sexauer; E M Saab
Journal:  AJR Am J Roentgenol       Date:  1995-09       Impact factor: 3.959

2.  Intravascular ultrasound diagnosis of a coronary artery pseudoaneurysm following percutaneous transluminal coronary angioplasty.

Authors:  T J Garrand; G S Mintz; J J Popma; S A Lewis; N A Vaughn; M B Leon
Journal:  Am Heart J       Date:  1993-03       Impact factor: 4.749

3.  Aortic aneurysms: growth rates measured with CT.

Authors:  Y Hirose; S Hamada; M Takamiya; S Imakita; H Naito; T Nishimura
Journal:  Radiology       Date:  1992-10       Impact factor: 11.105

4.  The natural history of thoracic aortic aneurysms.

Authors:  O E Dapunt; J D Galla; A M Sadeghi; S L Lansman; C K Mezrow; R A de Asla; C Quintana; S Wallenstein; A M Ergin; R B Griepp
Journal:  J Thorac Cardiovasc Surg       Date:  1994-05       Impact factor: 5.209

Review 5.  [Aortic pseudoaneurysm and acute myocardial infarct secondary to thoracic trauma].

Authors:  V Castelo; F Fernández; J R González-Juanatey; A Amaro; J M García Acuña; J Rubio; M Gil
Journal:  Rev Esp Cardiol       Date:  1994-10       Impact factor: 4.753

6.  Left hilar mass with obstruction of the main bronchus due to localized pseudoaneurysm of the thoracic aorta.

Authors:  J M Lukanich; A A Conlan
Journal:  Can J Surg       Date:  1996-02       Impact factor: 2.089

7.  Acute pseudoaneurysm formation complicating balloon dilation of native coarctation: treatment by delayed surgical repair.

Authors:  I C Huggon; I A Murdoch; A C Cooke; D R Anderson
Journal:  Pediatr Cardiol       Date:  1994 Nov-Dec       Impact factor: 1.655

8.  [A repair of the aortic pseudoaneurysm after ascending aortic grafting in acute type A dissection--a case report].

Authors:  I Fukuda; H Ohuchi; K Matsuzaki
Journal:  Nihon Kyobu Geka Gakkai Zasshi       Date:  1995-04

9.  Thoracoabdominal aortic aneurysm: observations regarding the natural course of the disease.

Authors:  E S Crawford; R W DeNatale
Journal:  J Vasc Surg       Date:  1986-04       Impact factor: 4.268

10.  Pseudoaneurysm of the ascending aorta following cardiac surgery.

Authors:  K L Sullivan; R M Steiner; S N Smullens; L Griska; S G Meister
Journal:  Chest       Date:  1988-01       Impact factor: 9.410

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.