Literature DB >> 9754978

Detection of the change point in oxygen uptake during an incremental exercise test using recursive residuals: relationship to the plasma lactate accumulation and blood acid base balance.

J A Zoladz1, Z Szkutnik, J Majerczak, K Duda.   

Abstract

The purpose of this study was to develop a method to determine the power output at which oxygen uptake (VO2) during an incremental exercise test begins to rise non-linearly. A group of 26 healthy non-smoking men [mean age 22.1 (SD 1.4) years, body mass 73.6 (SD 7.4) kg, height 179.4 (SD 7.5) cm, maximal oxygen uptake (VO2max) 3.726 (SD 0.363) l x min(-1)], experienced in laboratory tests, were the subjects in this study. They performed an incremental exercise test on a cycle ergometer at a pedalling rate of 70 rev x min(-1). The test started at a power output of 30 W, followed by increases amounting to 30 W every 3 min. At 5 min prior to the first exercise intensity, at the end of each stage of exercise protocol, blood samples (1 ml each) were taken from an antecubital vein. The samples were analysed for plasma lactate concentration [La]pl, partial pressure of O2 and CO2 and hydrogen ion concentration [H+]b. The lactate threshold (LT) in this study was defined as the highest power output above which [La-]pl showed a sustained increase of more than 0.5 mmol x l(-1) x step(-1). The VO2 was measured breath-by-breath. In the analysis of the change point (CP) of VO2 during the incremental exercise test, a two-phase model was assumed for the 3rd-min-data of each step of the test: Xi = at(i) + b + epsilon(i) for i = 1,2, ..., T, and E(Xi) > at(i) + b for i = T + 1, ..., n, where X1, ..., Xn are independent and epsilon(i) approximately N(0, sigma2). In the first phase, a linear relationship between VO2 and power output was assumed, whereas in the second phase an additional increase in VO2 above the values expected from the linear model was allowed. The power output at which the first phase ended was called the change point in oxygen uptake (CP-VO2). The identification of the model consisted of two steps: testing for the existence of CP and estimating its location. Both procedures were based on suitably normalised recursive residuals. We showed that in 25 out of 26 subjects it was possible to determine the CP-VO2 as described in our model. The power output at CP-VO2 amounted to 136.8 (SD 31.3) W. It was only 11 W -- non significantly -- higher than the power output corresponding to LT. The VO2 at CP-VO2 amounted to 1.828 (SD 0.356) l x min(-1) was [48.9 (SD 7.9)% VO2max]. The [La-]pl at CP-VO2, amounting to 2.57 (SD 0.69) mmol x l(-1) was significantly elevated (P < 0.01) above the resting level [1.85 (SD 0.46) mmol x l(-1)], however the [H+]b at CP-VO2 amounting to 45.1 (SD 3.0) nmol x l(-1), was not significantly different from the values at rest which amounted to 44.14 (SD 2.79) nmol x l(-1). An increase of power output of 30 W above CP-VO2 was accompanied by a significant increase in [H+]b above the resting level (P = 0.03).

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9754978     DOI: 10.1007/s004210050433

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  5 in total

1.  Validity of a customized submaximal treadmill protocol for determining VO2max.

Authors:  Cody J Strom; Robert W Pettitt; Luke M Krynski; Nicholas A Jamnick; Charles J Hein; Cherie D Pettitt
Journal:  Eur J Appl Physiol       Date:  2018-06-08       Impact factor: 3.078

2.  PhysioDroid: combining wearable health sensors and mobile devices for a ubiquitous, continuous, and personal monitoring.

Authors:  Oresti Banos; Claudia Villalonga; Miguel Damas; Peter Gloesekoetter; Hector Pomares; Ignacio Rojas
Journal:  ScientificWorldJournal       Date:  2014-09-10

3.  Plasma BCAA concentrations during exercise of varied intensities in young healthy men-the impact of endurance training.

Authors:  Anna Gawedzka; Marcin Grandys; Krzysztof Duda; Justyna Zapart-Bukowska; Jerzy A Zoladz; Joanna Majerczak
Journal:  PeerJ       Date:  2020-12-21       Impact factor: 2.984

4.  Validity of the revised Ekblom Bak cycle ergometer test in adults.

Authors:  Frida Björkman; Elin Ekblom-Bak; Örjan Ekblom; Björn Ekblom
Journal:  Eur J Appl Physiol       Date:  2016-06-16       Impact factor: 3.078

5.  Regulation of oxidative phosphorylation is different in electrically- and cortically-stimulated skeletal muscle.

Authors:  Bernard Korzeniewski
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.