Literature DB >> 9751680

New insights and observations in three-dimensional echocardiographic visualization of ventricular septal defects: experimental and clinical studies.

R E Kardon1, Q L Cao, N Masani, L Sugeng, S Supran, K G Warner, N G Pandian, G R Marx.   

Abstract

BACKGROUND: The positions, sizes, and shapes of ventricular septal defects (VSDs) can be difficult to assess by 2-dimensional echocardiography (2DE). Volume-rendered 3-dimensional echocardiography (3DE) can provide unique views of VSDs from the left ventricular (LV) side, allowing complete assessment of their circumference and spatial orientations to other anatomic structures. METHODS AND
RESULTS: Seventeen experimentally created defects of various locations, sizes, and shapes were imaged and reconstructed in 9 explanted porcine hearts. From an en face projection, major and minor axis diameters of the defects were measured, and these data were compared with direct anatomic measurements. Optimal reconstructions of the VSDs were obtained in all heart specimens, accurately depicting their positions and shapes. The correlations between 3DE and anatomy for the VSD major and minor axis diameters were y=1.0x+0.3 (r=0.88, P<0.001) and y=1.0x-1.4 (r =0.89, P<0.001), respectively. Good agreement between the 2 methods was demonstrated for all measurements. Our experience from the in vitro model was then applied to patient studies. Optimal LV en face reconstructions were obtained in 45 of 51 patients, permitting detailed assessment of the positions, sizes, and shapes of the VSDs. In the 25 patients with comparative surgical measurements, the correlations between 3DE and surgery for the VSD major and minor axis diameters were y =0. 81x+2.1 (r=0.92, P<0.001) and y=0.73x+2.0 (r=0.91, P<0.001), respectively. Good agreement was demonstrated between measurements made by 3DE and those obtained at surgery.
CONCLUSIONS: 3DE provides excellent visualization of various types of VSDs. From an LV en face projection, the positions, sizes, and shapes of VSDs can be accurately determined. Such precise imaging will be beneficial for surgical and catheter-based closure of difficult perimembranous and singular or multiple muscular VSDs.

Entities:  

Mesh:

Year:  1998        PMID: 9751680     DOI: 10.1161/01.cir.98.13.1307

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

Review 1.  [Echocardiographic evaluation in unoperated congenital heart disease in adults].

Authors:  A Geibel
Journal:  Herz       Date:  1999-06       Impact factor: 1.443

2.  Ventricular Septal Defect.

Authors: 
Journal:  Curr Treat Options Cardiovasc Med       Date:  1999-12

3.  Real time 3-D echocardiography in cardiac surgery.

Authors:  Akihiko Usui; Yoshimori Araki; Kohji Sakurai; Hiroomi Murayama; Masaharu Yoshikawa; Toshiaki Akita; Yuichi Ueda
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2004-11

4.  Three-dimensional echocardiography of ventricular septal defects.

Authors:  M Hoch; U Roemer; R Kozlik-Feldmann; A Fuchs; H Netz
Journal:  Images Paediatr Cardiol       Date:  2002-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.