Literature DB >> 9746250

Simultaneous determination of cyanide and thiocyanate in blood by ion chromatography with fluorescence and ultraviolet detection.

S Chinaka1, N Takayama, Y Michigami, K Ueda.   

Abstract

An ion chromatographic method for the simultaneous determination of cyanide and thiocyanate in blood has been developed. After extraction by adding water and methanol to blood, cyanide was derivatized with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product of 1-cyanobenz[f]isoindole. This compound was detected with high sensitivity by fluorometry and the underivatized thiocyanate was detected by ultraviolet absorption. The detection limits were 3.8 pmol ml(-1) for cyanide and 86 pmol ml(-1) for thiocyanate, and the recoveries from blood were ca. 83% and ca. 100%, respectively. The proposed method was successfully applied to the analysis of both anions in blood from smokers, non-smokers and fire victims.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9746250     DOI: 10.1016/s0378-4347(98)00176-5

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  6 in total

1.  New facile method to measure cyanide in blood.

Authors:  William C Blackledge; Charles W Blackledge; Alexa Griesel; Sari B Mahon; Matthew Brenner; Renate B Pilz; Gerry R Boss
Journal:  Anal Chem       Date:  2010-05-15       Impact factor: 6.986

2.  A disposable blood cyanide sensor.

Authors:  Yong Tian; Purnendu K Dasgupta; Sari B Mahon; Jian Ma; Matthew Brenner; Jian-Hua Wang; Gerry R Boss
Journal:  Anal Chim Acta       Date:  2013-02-01       Impact factor: 6.558

3.  Comment on "Rapid visual detection of blood cyanide" by C. Männel-Croisé and F. Zelder, Analytical Methods, 2012, 4, 2632.

Authors:  Akinde F Kadjo; Purnendu K Dasgupta; Gerry R Boss
Journal:  Anal Methods       Date:  2015-06-17       Impact factor: 2.896

4.  A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

Authors:  Qiyang Zhang; Naveen Maddukuri; Maojun Gong
Journal:  J Chromatogr A       Date:  2015-08-28       Impact factor: 4.759

5.  Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva.

Authors:  Marcin Urbanowicz; Kamila Sadowska; Dorota Pijanowska; Radosław Pomećko; Maria Bocheńska
Journal:  Sensors (Basel)       Date:  2020-05-15       Impact factor: 3.576

6.  Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

Authors:  Ewa Jaszczak; Marek Ruman; Sylwia Narkowicz; Jacek Namieśnik; Żaneta Polkowska
Journal:  J Anal Methods Chem       Date:  2017-11-21       Impact factor: 2.193

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.