Literature DB >> 9746249

Development of a coupled-column liquid chromatographic-tandem mass spectrometric method for the direct determination of betamethasone in urine.

A Polettini1, G Marrubini Bouland, M Montagna.   

Abstract

Different hyphenated liquid chromatographic (LC) and mass spectrometric (MS) techniques were investigated in order to set-up a method for the fast, direct analysis of betamethasone in hydrolysed and non-hydrolysed urine using large-volume sample injection. After the optimisation of the LC parameters using a traditional UV detector and of the thermospray and mass spectrometric parameters by flow injection, urine samples (0.5 ml) were submitted to analysis by either LC combined with tandem mass spectrometry (MS-MS), coupled-column LC (LC-LC) combined with single quadrupole MS, and LC-LC-MS-MS. Both the three-step configurations (LC-MS-MS and LC-LC-MS) did not provide satisfactory results: loss of sensitivity was noted in the case of LC-MS-MS (likely due to reduced efficiency in the ionisation of betamethasone in the thermospray owing to the presence of large amounts of matrix interference), while in the case of LC-LC-MS a high chemical noise resulting in insufficient selectivity of detection was observed. On the contrary, LC-LC-MS-MS analysis proved to meet the demand of high speed of analysis (sample throughput, 4.5 h(-1)), selectivity, and sensitivity (LOQ, 1 ng/ml; LOD, 0.2 ng/ml). Notwithstanding the complex analytical system adopted, the developed procedure was manageable and very robust, provided that at the beginning of each analytical session the performance of the system was controlled by checking the retention time of the analytes on the first analytical column with UV detection and by optimising vaporiser temperature of the thermospray by flow injection.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9746249     DOI: 10.1016/s0378-4347(98)00177-7

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  2 in total

1.  No variation of physical performance and perceived exertion after adrenal gland stimulation by synthetic ACTH (Synacthen) in cyclists.

Authors:  Norbert Baume; Graeme Steel; Tony Edwards; Eric Thorstensen; Benjamin F Miller
Journal:  Eur J Appl Physiol       Date:  2008-06-27       Impact factor: 3.078

2.  Determination of Glucocorticoids in UPLC-MS in Environmental Samples from an Occupational Setting.

Authors:  Enrico Oddone; Sara Negri; Massimo Bellinzona; Silvia Martino; Marcello Di Tuccio; Elena Grignani; Danilo Cottica; Marcello Imbriani
Journal:  Int J Anal Chem       Date:  2015-03-03       Impact factor: 1.885

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.