Literature DB >> 9745158

Unsatisfactory detection of an in vivo haemolytic anti-vel by the gel test.

J Neppert1, L Bartz, C Clasen.   

Abstract

BACKGROUND AND OBJECTIVES: A patient experienced a severe haemolytic transfusion reaction. Neither the haemolytic property nor the specificity of the causative antibody had been sufficiently recognised when performing a microcolumn gel test.
MATERIALS AND METHODS: Subsequent to the transfusion reaction, the serological property and specificity of the causative antibody were analysed. Tube and gel test methods were compared, as were various reagent red cell specimens and their constituents.
RESULTS: A haemolytic anti-Vel was detected in the tube test. In contrast, the particular commercial gel test kit used did not reveal the haemolytic property or specificity of the antibody. Our experiments suggest that this was apparently due to the presence of EDTA in the low ionic strength saline solution of the test kit.
CONCLUSIONS: In rare cases life-treatening haemolytic activity of an irregular blood group antibody may be undetected by a commericial microcolum gel test kit in which EDTA is a constituent.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9745158

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  2 in total

1.  A newly recognized blood group in domestic shorthair cats: the Mik red cell antigen.

Authors:  Nicole M Weinstein; Marie-Claude Blais; Kimberly Harris; Donna A Oakley; Lillian R Aronson; Urs Giger
Journal:  J Vet Intern Med       Date:  2007 Mar-Apr       Impact factor: 3.333

2.  Disruption of SMIM1 causes the Vel- blood type.

Authors:  Bryan A Ballif; Virginie Helias; Thierry Peyrard; Cécile Menanteau; Carole Saison; Nicole Lucien; Sébastien Bourgouin; Maude Le Gall; Jean-Pierre Cartron; Lionel Arnaud
Journal:  EMBO Mol Med       Date:  2013-04-15       Impact factor: 12.137

  2 in total