Literature DB >> 9741527

Intramural delivery of a specific tyrosine kinase inhibitor with biodegradable stent suppresses the restenotic changes of the coronary artery in pigs in vivo.

T Yamawaki1, H Shimokawa, T Kozai, K Miyata, T Higo, E Tanaka, K Egashira, T Shiraishi, H Tamai, K Igaki, A Takeshita.   

Abstract

OBJECTIVES: This study was designed to examine whether or not intramural delivery of ST638 (a specific tyrosine kinase inhibitor) with biodegradable stent can suppress the restenotic changes of the coronary artery in vivo.
BACKGROUND: Clinical and animal studies demonstrated that restenosis after coronary intervention results from a combined effect of neointimal formation and geometric remodeling (decrease in total cross-sectional area). Thus, the most effective strategy to prevent the restenosis appears to inhibit both the neointimal formation and geometric remodeling by antiproliferative agent and stent, respectively. We have previously shown that ST638 markedly suppresses the restenotic changes of the porcine coronary artery when applied from the adventitial site.
METHODS: A poly-L-lactic acid biodegradable stent was coated with either ST638 (0.8 mg) or equimolar of its inactive metabolite, ST494. A pair of these stents were implanted alternatively in the left anterior descending or circumflex coronary artery in pigs (n=6). Three weeks after the procedure, coronary stenosis was assessed by angiography followed by histological examination.
RESULTS: Coronary stenosis was significantly less at the ST638 stent site than at the ST494 stent site (47+/-5% vs. 25+/-4%, p < 0.01). Histological examination also showed that the extent of neointimal formation and that of geometric remodeling were significantly less at the ST638 stent site than at the ST494 stent site (p < 0.05).
CONCLUSIONS: These results indicate that intramural delivery of a specific tyrosine kinase inhibitor with biodegradable stent overcomes the proliferative stimuli caused by balloon injury, the stent itself, and the drug coating on the stent, resulting in the suppression of the restenotic changes of the coronary artery in vivo. This strategy might also be useful in the clinical setting in humans.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9741527     DOI: 10.1016/s0735-1097(98)00312-x

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  19 in total

Review 1.  Biologic alternatives to stents and grafts.

Authors:  N M Caplice
Journal:  Curr Cardiol Rep       Date:  2001-01       Impact factor: 2.931

2.  A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits.

Authors:  M Peuster; P Wohlsein; M Brügmann; M Ehlerding; K Seidler; C Fink; H Brauer; A Fischer; G Hausdorf
Journal:  Heart       Date:  2001-11       Impact factor: 5.994

Review 3.  The cell cycle: a critical therapeutic target to prevent vascular proliferative disease.

Authors:  Thierry Charron; Nafiseh Nili; Bradley H Strauss
Journal:  Can J Cardiol       Date:  2006-02       Impact factor: 5.223

Review 4.  New drug-eluting stent concepts.

Authors:  Rainer Wessely
Journal:  Nat Rev Cardiol       Date:  2010-03-02       Impact factor: 32.419

Review 5.  The development of carotid stent material.

Authors:  Dongsheng He; Wenhua Liu; Tao Zhang
Journal:  Interv Neurol       Date:  2015-03

6.  Comparison of early vascular morphological changes between bioresorbable poly-L-lactic acid scaffolds and metallic stents in porcine iliac arteries.

Authors:  Yasuhito Sekimoto; Hideaki Obara; Kentaro Matsubara; Naoki Fujimura; Hirohisa Harada; Yuko Kitagawa
Journal:  Organogenesis       Date:  2017-01-19       Impact factor: 2.500

7.  Novel biodegradable stents for benign esophageal strictures following endoscopic submucosal dissection.

Authors:  Yasuharu Saito; Toyohiko Tanaka; Akira Andoh; Hideki Minematsu; Kazunori Hata; Tomoyuki Tsujikawa; Norihisa Nitta; Kiyoshi Murata; Yoshihide Fujiyama
Journal:  Dig Dis Sci       Date:  2007-08-23       Impact factor: 3.199

Review 8.  Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys.

Authors:  Patrick K Bowen; Emily R Shearier; Shan Zhao; Roger J Guillory; Feng Zhao; Jeremy Goldman; Jaroslaw W Drelich
Journal:  Adv Healthc Mater       Date:  2016-04-20       Impact factor: 9.933

Review 9.  Local drug delivery to prevent restenosis.

Authors:  Stephen M Seedial; Soumojit Ghosh; R Scott Saunders; Pasithorn A Suwanabol; Xudong Shi; Bo Liu; K Craig Kent
Journal:  J Vasc Surg       Date:  2013-05       Impact factor: 4.268

10.  Usefulness of biodegradable stents constructed of poly-l-lactic acid monofilaments in patients with benign esophageal stenosis.

Authors:  Yasuharu Saito; Toyohiko Tanaka; Akira Andoh; Hideki Minematsu; Kazunori Hata; Tomoyuki Tsujikawa; Norihisa Nitta; Kiyoshi Murata; Yoshihide Fujiyama
Journal:  World J Gastroenterol       Date:  2007-08-07       Impact factor: 5.742

View more