Literature DB >> 9741387

A novel method for chronic measurement of pleural pressure in conscious rats.

D J Murphy1, J P Renninger, K A Gossett.   

Abstract

Pleural pressures are used to evaluate lung function and are generally measured acutely in anesthetized animals. Previous attempts to measure pleural pressure chronically in conscious animals have involved surgical implantation of pressure-sensitive catheters directly into the pleural cavity. The success of these techniques has been limited by lung damage and/or tissue growth and encapsulation of the pressure-sensitive catheter with damping or loss of the signal. These problems have been eliminated by developing a novel surgical procedure for placement of a pressure-sensitive catheter beneath the pleural surface. The catheter (attached to a radiotelemetry transmitter) is surgically implanted beneath the serosal layer of the esophagus within the thoracic cavity. This is accomplished by making a small incision in the serosal layer of the esophagus caudal to the diaphragm and advancing the catheter cranially into the thoracic cavity until pressure changes are maximal. The accuracy of these measurements was verified by comparison with direct pleural pressure measurements over the range of -3 to -34 cm H2O. The pleural pressure changes remained constant for at least 14 weeks following surgery, and there was no evidence of tissue damage or growth around the catheter. This novel method for measuring pleural pressure chronically in conscious rats will facilitate evaluation of the effects of drugs, environmental agents, or disease on respiratory function by allowing repeated and simultaneous measurements of both ventilatory (breathing) patterns and lung function in conscious animals.

Entities:  

Mesh:

Year:  1998        PMID: 9741387     DOI: 10.1016/s1056-8719(98)00008-2

Source DB:  PubMed          Journal:  J Pharmacol Toxicol Methods        ISSN: 1056-8719            Impact factor:   1.950


  7 in total

1.  Correction of respiratory disorders in a mouse model of Rett syndrome.

Authors:  Ana P L Abdala; Mathias Dutschmann; John M Bissonnette; Julian F R Paton
Journal:  Proc Natl Acad Sci U S A       Date:  2010-10-04       Impact factor: 11.205

2.  Positive end-expiratory pressure and pressure support in peripheral airways obstruction : work of breathing in intubated children.

Authors:  Alan S Graham; Girish Chandrashekharaiah; Agop Citak; Randall C Wetzel; Christopher J L Newth
Journal:  Intensive Care Med       Date:  2006-11-17       Impact factor: 17.440

3.  Applications of a novel radiotelemetry method for the measurement of intrathoracic pressures and physiological rhythms in freely behaving mice.

Authors:  Andrew J Foster; Jade P Marrow; Melissa A Allwood; Keith R Brunt; Jeremy A Simpson
Journal:  J Appl Physiol (1985)       Date:  2020-09-03

4.  Comparing thoracic and intra-nasal pressure transients to monitor active odor sampling during odor-guided decision making in the mouse.

Authors:  Johannes Reisert; Glen J Golden; Koichi Matsumura; Matt Smear; Dmitry Rinberg; Alan Gelperin
Journal:  J Neurosci Methods       Date:  2013-09-19       Impact factor: 2.390

5.  Intermittent hypercapnic hypoxia induces respiratory hypersensitivity to fentanyl accompanied by tonic respiratory depression by endogenous opioids.

Authors:  Allison D Brackley; Mary Ann Andrade; Glenn M Toney
Journal:  J Physiol       Date:  2020-06-14       Impact factor: 5.182

6.  Lung function measurements in rodents in safety pharmacology studies.

Authors:  Heinz Gerd Hoymann
Journal:  Front Pharmacol       Date:  2012-08-28       Impact factor: 5.810

7.  Chronic upper airway obstruction induces abnormal sleep/wake dynamics in juvenile rats.

Authors:  Gideon Gradwohl; Nilly Berdugo-Boura; Yael Segev; Ariel Tarasiuk
Journal:  PLoS One       Date:  2014-05-13       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.