Literature DB >> 9738226

[Management of complicated incisional hernias with underlay-technique implanted polypropylene mesh. An effective technique in French hernia surgery].

A W Trupka1, K K Hallfeldt, S Schmidbauer, L Schweiberer.   

Abstract

UNLABELLED: Incisional hernia repair with conventional techniques (simple closure, Mayo-technique) is associated with unacceptable recurrence rates of 30-50%. Therefore, surgical repair using different prosthetic biomaterials is becoming increasingly popular. Further to favourable results by French hernia surgeons, we studied the results of underlay prosthetic mesh repair using polypropylene mesh in complicated and recurrent incisional hernias.
METHOD: After preparation and excision of the entire hernia sac, the posterior rectus sheath is freed from the muscle bellies on both sides. The peritoneum and posterior rectus sheaths are closed with a continuous looped polyglyconate suture. The prosthesis used for midline hernias is positioned on the posterior rectus sheath and extends far beyond the borders of the myoaponeurotic defect. The anterior rectus sheath is closed with a continuous suture. The prosthesis for lumbar and subcostal hernias is placed in a prepared space between the transverse and oblique muscles. Intraperitoneal placement of the mesh must be avoided.
RESULTS: Between January 1996 and August 1997 we performed a total of 33 incisional hernia repairs (14 primary hernias, 19 recurrent hernias) using this technique (16 women, 17 men, mean age 56.19 +/- 12.92 years). Local complications occurred in four patients (12%): superficial wound infection (n = 2), postoperative bleeding, requiring reoperation (n = 1), minor hemato-seroma (n = 1). One patient suddenly died on the 3rd post-operative day from severe pulmonary embolism (mortality 3%). Twenty-two patients with a minimum follow up to 6 months were re-examined clinically. The average follow-up time for this group was 9 months (range 6-17 months). To date no recurrent hernias have been observed. There were only minor complaints like "a feeling of tension" in the abdominal wall (n = 3) and slight pain under physical stress (n = 6).
CONCLUSIONS: The use of prosthetic mesh should be considered for repair of large or recurrent incisional hernias, especially in high-risk patients (obesity, obstructive lung disease) and complicated hernias. The aforementioned technique of underlay prosthetic repair using polypropylene mesh fixed onto the posterior rectus sheath allows for anatomical and consolidated reconstruction of the damaged abdominal wall with excellent results and low complication rates.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9738226     DOI: 10.1007/s001040050488

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  11 in total

1.  Laparoscopic ventral hernia repair.

Authors:  W Scott Melvin; David Renton
Journal:  World J Surg       Date:  2011-07       Impact factor: 3.352

2.  [Treatment of abdominal wall defects, including abdominal relaxation].

Authors:  C Langer; H Becker
Journal:  Chirurg       Date:  2006-05       Impact factor: 0.955

Review 3.  Parastomal hernia repair and reinforcement: the role of biologic and synthetic materials.

Authors:  Suzanne Gillern; Joshua I S Bleier
Journal:  Clin Colon Rectal Surg       Date:  2014-12

4.  Treatment of large incisional abdominal wall hernias, using a modified preperitoneal prosthetic mesh repair.

Authors:  G Ohana; Z Bramnik; A Miller; D Seror; A Ariche; N Bachar Gil; R Belavsky; Z Dreznik
Journal:  Hernia       Date:  2006-02-02       Impact factor: 4.739

5.  Impact of mesh positioning on foreign body reaction and collagenous ingrowth in a rabbit model of open incisional hernia repair.

Authors:  M Binnebösel; C D Klink; J Otto; J Conze; P L Jansen; M Anurov; V Schumpelick; K Junge
Journal:  Hernia       Date:  2009-11-05       Impact factor: 4.739

6.  Simplified technique for incisional hernia repair with mesh prosthesis.

Authors:  G Guzmán-Valdivia; O Medina; A Martínez
Journal:  Hernia       Date:  2003-09-16       Impact factor: 4.739

7.  Three-dimensional mesh for ventral hernias: a new technique for an old problem.

Authors:  M del Pozo; P Marín
Journal:  Hernia       Date:  2003-09-16       Impact factor: 4.739

8.  Incisional hernia repair after orthotopic liver transplantation: a technique employing an inlay/onlay polypropylene mesh.

Authors:  V Müller; M Lehner; P Klein; W Hohenberger; R Ott
Journal:  Langenbecks Arch Surg       Date:  2003-06-17       Impact factor: 3.445

9.  Repair of large midline incisional hernias with polypropylene mesh: comparison of three operative techniques.

Authors:  T S de Vries Reilingh; D van Geldere; Blam Langenhorst; D de Jong; G J van der Wilt; H van Goor; R P Bleichrodt
Journal:  Hernia       Date:  2003-10-28       Impact factor: 4.739

10.  Hernia recurrence as a problem of biology and collagen.

Authors:  Uwe Klinge; Marcel Binnebösel; Raphael Rosch; Peter Mertens
Journal:  J Minim Access Surg       Date:  2006-09       Impact factor: 1.407

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.