Literature DB >> 9734746

Estimation of total body water in very-low-birth-weight infants by using anthropometry with and without bioelectrical impedance and H2[(18)O].

C V Raghavan1, D M Super, R L Chatburn, S M Savin, A A Fanaroff, S C Kalhan.   

Abstract

The usefulness of bioelectrical impedance (BI) with anthropometry to measure total body water (TBW) was evaluated in very-low-birth-weight (VLBW) infants. A specific regression equation to measure TBW in a VLBW population was developed by simultaneously using the H2[(18)O] dilution method and BI in 12 infants with a gestational age of 24-30 wk and weighing <1200 g at birth. After an oral dose of H2[(18)O], the tracer dilution was measured in expired carbon dioxide. BI measurements were made with a model BIA-101 apparatus (RJL Systems, Detroit). Electrodes were placed in the standard position as well as proximally on the leg and the forearm. The best correlation was observed between body weight and TBW (r = 0.989). For BI, the best correlation was obtained when gestational age was used as a covariable along with body weight and crown-heel length (r = 0.985). The correlation was comparable with proximal electrode placement (r = 0.985). The new correlation was evaluated in 6 infants weighing < 1008 g. A significant correlation between BI and H2[(18)O]-measured TBW was observed (r = 0.988). Published regression equations for infants consistently gave higher estimates of TBW in another group of 14 infants weighing <1200 g than did the new correlations. TBW represented 84-95% of body weight in these VLBW infants. TBW could be computed simply from body weight alone. Use of BI and length as covariables did not add significantly to the estimate of TBW in VLBW infants.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9734746     DOI: 10.1093/ajcn/68.3.668

Source DB:  PubMed          Journal:  Am J Clin Nutr        ISSN: 0002-9165            Impact factor:   7.045


  7 in total

Review 1.  Deuterium and its impact on living organisms.

Authors:  Veronika Kselíková; Milada Vítová; Kateřina Bišová
Journal:  Folia Microbiol (Praha)       Date:  2019-07-27       Impact factor: 2.099

2.  Body composition in preterm infants: a systematic review on measurement methods.

Authors:  Dana F J Yumani; Dide de Jongh; Johannes C F Ket; Harrie N Lafeber; Mirjam M van Weissenbruch
Journal:  Pediatr Res       Date:  2022-08-22       Impact factor: 3.953

Review 3.  Body composition measurement for the preterm neonate: using a clinical utility framework to translate research tools into clinical care.

Authors:  Katherine A Bell; Sara E Ramel; Daniel T Robinson; Carol L Wagner; Brian Scottoline; Mandy B Belfort
Journal:  J Perinatol       Date:  2022-10-06       Impact factor: 3.225

4.  Prediction equations for body-fat percentage in Indian infants and young children using skinfold thickness and mid-arm circumference.

Authors:  Bandana Sen; Kaushik Bose; Saijuddin Shaikh; Dilip Mahalanabis
Journal:  J Health Popul Nutr       Date:  2010-06       Impact factor: 2.000

5.  Estimation of fat-free mass in Asian neonates using bioelectrical impedance analysis.

Authors:  Mya-Thway Tint; Leigh C Ward; Shu E Soh; Izzuddin M Aris; Amutha Chinnadurai; Seang Mei Saw; Peter D Gluckman; Keith M Godfrey; Yap-Seng Chong; Michael S Kramer; Fabian Yap; Barbara Lingwood; Yung Seng Lee
Journal:  Br J Nutr       Date:  2016-02-09       Impact factor: 3.718

6.  The influence of body position on bioelectrical impedance spectroscopy measurements in young children.

Authors:  Jaz Lyons-Reid; Leigh C Ward; Mya-Thway Tint; Timothy Kenealy; Keith M Godfrey; Shiao-Yng Chan; Wayne S Cutfield
Journal:  Sci Rep       Date:  2021-05-14       Impact factor: 4.379

7.  Bioelectrical Impedance Analysis-An Easy Tool for Quantifying Body Composition in Infancy?

Authors:  Jaz Lyons-Reid; Leigh C Ward; Timothy Kenealy; Wayne Cutfield
Journal:  Nutrients       Date:  2020-03-27       Impact factor: 5.717

  7 in total