Literature DB >> 9728847

Substantial changes in arterial blood gases during thoracoscopic surgery can be missed by conventional intermittent laboratory blood gas analyses.

M Zaugg1, E Lucchinetti, M P Zalunardo, S Zumstein, D R Spahn, T Pasch, A Zollinger.   

Abstract

UNLABELLED: Substantial and clinically relevant changes in arterial blood gases are likely to occur during thoracoscopic surgery with one-lung ventilation (OLV). We hypothesized that they may be missed when using the conventional intermittent blood gas sampling practice. Therefore, during 30 thoracoscopic procedures with OLV, the sampling intervals between consecutive intermittent laboratory blood gas analyses (BGA) were evaluated with respect to changes of PaO2, PaCO2, and pHa ([H+]) using a continuous intraarterial blood gas monitoring system. Frequency and timing of BGA were based on the clinical judgment of 16 experienced anesthesiologists who were blinded to the continuously measured values. Extreme fluctuations of PaO2 (37-625 mm Hg), PaCO2 (27-56 mm Hg), and pHa (7.24-7.51) were observed by continuous blood gas monitoring. During 63% of all sampling intervals, PaO2 decreased >20% compared with the preceding BGA value, which remained undetected by intermittent analysis. In 10 patients with a continuously measured minimal PaO2 value < or = 60 mm Hg, the preceding BGA overestimated this minimal PaO2 by > 47%. Correspondingly, PaCO2 increases of > 10% were observed in 35% of all sampling intervals, and [H+] increases of > 10% were observed in 24% of all sampling intervals. Because these blood gas changes were not reliably detected by using noninvasive monitoring and their magnitude is not predictable during OLV, intermittent BGA with short sampling intervals is warranted. In critical cases, continuous blood gas monitoring may be helpful. IMPLICATIONS: The magnitude of blood gas changes during thoracoscopic surgery with one-lung ventilation is not predictable and not reliably detected by noninvasive monitoring. Using a continuous intraarterial blood gas monitoring device, we demonstrated that intermittent laboratory blood gas analysis with short sampling intervals is warranted to detect arterial hypoxemia.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9728847     DOI: 10.1097/00000539-199809000-00030

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

1.  Experiences with continuous intra-arterial blood gas monitoring: precision and drift of a pure optode-system.

Authors:  Matthias Menzel; Jens Soukup; Dirk Henze; Kai Engelbrecht; Maik Senderreck; Alexander Scharf; Andreas Rieger; Stefan Grond
Journal:  Intensive Care Med       Date:  2003-09-03       Impact factor: 17.440

2.  Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

Authors:  Stefan Boehme; Bastian Duenges; Klaus U Klein; Volker Hartwich; Beate Mayr; Jolanda Consiglio; James E Baumgardner; Klaus Markstaller; Reto Basciani; Andreas Vogt
Journal:  PLoS One       Date:  2013-04-02       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.