The TEST 1 automated system: a new method for measuring the erythrocyte sedimentation rate.

M Plebani1, S De Toni, M C Sanzari, D Bernardi, E Stockreiter.   

Abstract

We evaluated performance of the TEST 1 (SIRE Analytical Systems, Udine, Italy), a fully automated analyzer for the measurement of the erythrocyte sedimentation rate (ESR). Intra-assay reproducibility was satisfactory for a wide range of ESR values, whereas there was a significant decrease in ESR data when the samples were stored at 4 degrees C for up to 24 hours. We compared TEST 1 with the Westergren ESR method approved by the International Council for Standardization in Haematology (ICSH) and with the Diesse Ves-Matic analyzer Linear regression analysis comparing the TEST 1 and the ICSH reference method yielded satisfactory correlations for K3 EDTA- and sodium citrate-anticoagulated samples. Bland-Altman analysis showed no evidence of a systematic bias between the TEST 1 and the reference method. A close correlation was found between the TEST 1 system and the Diesse Ves-Matic analyzer despite a significant positive systematic bias. Reference values for men and women were analyzed according to nonparametric statistics. The TEST 1 was easy to use, had a satisfactory operative practicability required minimal maintenance, and reduced contact with potential biohazards. This system enables the determination of ESR with any common standard-sized tube; the use of samples anticoagulated with K3 EDTA can widely reduce the workload in clinical laboratories.

Entities:  

Mesh:

Year:  1998        PMID: 9728608     DOI: 10.1093/ajcp/110.3.334

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  9 in total

1.  Differences in erythrocyte sedimentation rates using a modified Westergren method and an alternate method.

Authors:  Elise Schapkaitz; Shilla RabuRabu; Marcel Engelbrecht
Journal:  J Clin Lab Anal       Date:  2018-08-26       Impact factor: 2.352

2.  A portable rotating disc as blood rheometer.

Authors:  Rahul Agarwal; Arnab Sarkar; Subhechchha Paul; Suman Chakraborty
Journal:  Biomicrofluidics       Date:  2019-12-02       Impact factor: 2.800

3.  Quality of life in adult patients with Familial Mediterranean fever living in Germany or Turkey compared to healthy subjects: a study evaluating the effect of disease severity and country of residence.

Authors:  Arnd Giese; Mustafa Kurucay; Levent Kilic; Ahmet Örnek; Süleyman Nahit Şendur; Elke Lainka; Bernhard Ferdinand Henning
Journal:  Rheumatol Int       Date:  2012-12-29       Impact factor: 2.631

4.  A Comparison Between the StaRRsed Auto-Compact Erythrocyte Sedimentation Rate Instrument and the Westergren Method.

Authors:  Juha Horsti; Riikka Rontu; Auni Collings
Journal:  J Clin Med Res       Date:  2010-12-11

5.  Test-1 analyzer and conventional Westergren method for erythrocyte sedimentation rate: A comparative study between two laboratories.

Authors:  Cigdem Sonmez; Ozlem Ceylan Dogan; Aysegul Ozturk Kaymak; Nedim Akkaya; Kadir Okhan Akin; Gulcan Guntas
Journal:  J Clin Lab Anal       Date:  2018-01-17       Impact factor: 2.352

6.  Multiple and Periodic Measurement of RBC Aggregation and ESR in Parallel Microfluidic Channels under On-Off Blood Flow Control.

Authors:  Yang Jun Kang; Byung Jun Kim
Journal:  Micromachines (Basel)       Date:  2018-06-24       Impact factor: 2.891

7.  Factors influencing erythrocyte sedimentation rate in adults: New evidence for an old test.

Authors:  Vanessa Alende-Castro; Manuela Alonso-Sampedro; Nuria Vazquez-Temprano; Carmen Tuñez; Daniel Rey; Carmen García-Iglesias; Bernardo Sopeña; Francisco Gude; Arturo Gonzalez-Quintela
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

8.  Subclinical inflammatory status in Rett syndrome.

Authors:  Alessio Cortelazzo; Claudio De Felice; Roberto Guerranti; Cinzia Signorini; Silvia Leoncini; Alessandra Pecorelli; Gloria Zollo; Claudia Landi; Giuseppe Valacchi; Lucia Ciccoli; Luca Bini; Joussef Hayek
Journal:  Mediators Inflamm       Date:  2014-01-06       Impact factor: 4.711

9.  Comparison of the erythrocyte sedimentation rate measured by the Micro Test 1 sedimentation analyzer and the conventional Westergren method.

Authors:  Serap Arikan; Nalan Akalin
Journal:  Ann Saudi Med       Date:  2007 Sep-Oct       Impact factor: 1.526

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.