Literature DB >> 9728172

Prediction of postoperative knee flexion in Insall-Burstein II total knee arthroplasty.

D J Schurman1, A Matityahu, S B Goodman, W Maloney, S Woolson, H Shi, D A Bloch.   

Abstract

Postoperative knee flexion in patients undergoing Insall-Burstein-II total knee arthroplasty at 2 years was evaluated regarding two basic questions: what groups of patients gain or lose the most flexion and what groups of patients have the best or worst postoperative flexion. Thirteen preoperative variables (maximum flexion, flexion arc, tibiofemoral angle, quadriceps strength, extensor lag, Knee Society score, Knee Society patient assessment, gender, age, height, weight, diagnosis, and surgeon) and four postoperative variable (leg length change, tibiofemoral angle, distance from patella to the joint line, and the tibial prosthesis anteroposterior translation on a lateral radiograph) were used in an attempt to explain postoperative flexion. The analysis was performed on 164 consecutive Insall-Burstein-II total knees in which the data were gathered prospectively on a time oriented medical record database. A regression tree analysis was used to identify several groups of patients, characterized by preoperative factor values, who had markedly above average performance on postoperative flexion. The preoperative factors identified include preoperative flexion, flexion arc, tibiofemoral angle, extensor lag, diagnosis, and age. The only postoperative variable of significance was tibiofemoral angle. Among the potential determinants of postoperative flexion that failed to appear predictive were the Knee Society scores and surgeon. Preoperative flexion is known to be a critical determinant of postoperative flexion in total knee replacement. However, in the current study, preoperative flexion accounted for only half of the difference between the best (122 degrees) and the worst (88 degrees) group, as determined with regression tree analysis.

Entities:  

Mesh:

Year:  1998        PMID: 9728172     DOI: 10.1097/00003086-199808000-00020

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  Significant effect of the posterior tibial slope and medial/lateral ligament balance on knee flexion in total knee arthroplasty.

Authors:  Eisaku Fujimoto; Yoshiaki Sasashige; Yasuji Masuda; Takashi Hisatome; Akio Eguchi; Tetsuo Masuda; Mikiya Sawa; Yoshinori Nagata
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-30       Impact factor: 4.342

2.  Residual posterior femoral condyle osteophyte affects the flexion range after total knee replacement.

Authors:  W P Yau; K Y Chiu; W M Tang; T P Ng
Journal:  Int Orthop       Date:  2005-09-16       Impact factor: 3.075

3.  Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Kiyonori Mizuno; Hirotsugu Muratsu; Nobuhiro Tsumura; Naomasa Fukase; Seiji Kubo; Shinichi Yoshiya; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-04-25       Impact factor: 4.342

4.  Preoperative laxity in osteoarthritis patients undergoing total knee arthroplasty.

Authors:  Yoshinori Ishii; Hideo Noguchi; Yoshikazu Matsuda; Hiroshi Kiga; Mitsuhiro Takeda; Shin-Ichi Toyabe
Journal:  Int Orthop       Date:  2007-10-16       Impact factor: 3.075

5.  Influence of intra-operative parameters on postoperative early recovery of active knee flexion in posterior-stabilized total knee arthroplasty.

Authors:  Kanto Nagai; Hirotsugu Muratsu; Tomoyuki Matsumoto; Akihiro Maruo; Hidetoshi Miya; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2013-07-23       Impact factor: 3.075

6.  Influence of intra-operative joint gaps on post-operative flexion angle in posterior cruciate-retaining total knee arthroplasty.

Authors:  Koji Takayama; Tomoyuki Matsumoto; Seiji Kubo; Hirotsugu Muratsu; Kazunari Ishida; Takehiko Matsushita; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-01       Impact factor: 4.342

7.  Importance of knee flexion range of motion during the acute phase after total knee arthroplasty.

Authors:  Tomohiro Oka; Osamu Wada; Tsuyoshi Asai; Hideto Maruno; Kiyonori Mizuno
Journal:  Phys Ther Res       Date:  2020-08-05

8.  Correlation between preoperative and postoperative knee kinematics in total knee arthroplasty using cruciate retaining designs.

Authors:  Jong Keun Seon; Ju Kwon Park; Mun Su Jeong; Woo Bin Jung; Kyung Soon Park; Taek Rim Yoon; Eun Kyoo Song
Journal:  Int Orthop       Date:  2010-04-30       Impact factor: 3.075

9.  Predicting functional performance and range of motion outcomes after total knee arthroplasty.

Authors:  Michael J Bade; John M Kittelson; Wendy M Kohrt; Jennifer E Stevens-Lapsley
Journal:  Am J Phys Med Rehabil       Date:  2014-07       Impact factor: 2.159

10.  Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Akihiko Toda; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-03-13       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.