Literature DB >> 9727947

Asymmetric spin-echo imaging of magnetically inhomogeneous systems: theory, experiment, and numerical studies.

L A Stables1, R P Kennan, J C Gore.   

Abstract

The ability of the asymmetric spin-echo (ASE) pulse sequence to provide different degrees of spin-echo (SE)-type and gradient-echo (GE)-type contrast when imaging media containing magnetic inhomogeneities is investigated. The dependence of the ASE signal on the size of magnetic field perturbers is examined using theory, computer simulations, and experiment. A theoretical prediction of the ASE signal is obtained using the Anderson-Weiss mean field theory, the results of which are qualitatively supported by computer simulations and experimental studies. It is shown that the ASE sequence can be used to tune the range of perturber sizes that provide the largest contributions to susceptibility contrast effects.

Mesh:

Substances:

Year:  1998        PMID: 9727947     DOI: 10.1002/mrm.1910400314

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

Review 1.  Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Authors:  A M Howseman; R W Bowtell
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

2.  Quantitative measurements of cerebral blood oxygen saturation using magnetic resonance imaging.

Authors:  H An; W Lin
Journal:  J Cereb Blood Flow Metab       Date:  2000-08       Impact factor: 6.200

3.  Absolute and relative contributions of BOLD effects to the muscle functional MRI signal intensity time course: effect of exercise intensity.

Authors:  Bruce M Damon; Megan C Wadington; Jennifer L Hornberger; Drew A Lansdown
Journal:  Magn Reson Med       Date:  2007-08       Impact factor: 4.668

4.  Dual gradient-echo MRI of post-contraction changes in skeletal muscle blood volume and oxygenation.

Authors:  Bruce M Damon; Jennifer L Hornberger; Megan C Wadington; Drew A Lansdown; Jane A Kent-Braun
Journal:  Magn Reson Med       Date:  2007-04       Impact factor: 4.668

Review 5.  The physics of functional magnetic resonance imaging (fMRI).

Authors:  Richard B Buxton
Journal:  Rep Prog Phys       Date:  2013-09-04

Review 6.  Physiological basis of muscle functional MRI.

Authors:  Bruce M Damon; Elizabeth A Louie; Otto A Sanchez
Journal:  J Gravit Physiol       Date:  2007-07

7.  Dispersion of relaxation rates in the rotating frame under the action of spin-locking pulses and diffusion in inhomogeneous magnetic fields.

Authors:  John T Spear; Zhongliang Zu; John C Gore
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

8.  Comparison of R2' measurement methods in the normal brain at 3 Tesla.

Authors:  Wendy Ni; Thomas Christen; Zungho Zun; Greg Zaharchuk
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

Review 9.  MRI-based methods for quantification of the cerebral metabolic rate of oxygen.

Authors:  Zachary B Rodgers; John A Detre; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2016-04-18       Impact factor: 6.200

10.  Quantitative β mapping for calibrated fMRI.

Authors:  Christina Y Shu; Basavaraju G Sanganahalli; Daniel Coman; Peter Herman; Douglas L Rothman; Fahmeed Hyder
Journal:  Neuroimage       Date:  2015-11-24       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.