Literature DB >> 9727806

Hydrogen peroxide in exhaled air of healthy children: reference values.

Q Jöbsis1, H C Raatgeep, S L Schellekens, W C Hop, P W Hermans, J C de Jongste.   

Abstract

An increased content of hydrogen peroxide (H2O2), a marker of inflammation, has been described in the condensate of exhaled air from adults and children with inflammatory lung disorders, including asthma. However, the normal range of [H2O2] in the exhaled air condensate from healthy children has not been established. Therefore, the aim of this study was to determine the reference range of exhaled [H2O2] in healthy school-aged children. Ninety-three healthy nonsmoking children (48 female and 45 male, mean age 10 yrs, range 8-13 yrs), with a negative history for allergy, eczema or respiratory disease and with a normal lung function, participated. Exhaled air condensate was examined fluorimetrically for the presence of H2O2. In addition, the reproducibility of [H2O2] within subjects and between days and the stability of [H2O2] during storage at -20 degrees C were assessed. The median [H2O2] in the exhaled air condensate of all children was 0.13 microM, with a 2.5-97.5% reference range of <0.01-0.48 microM. No significant difference existed between males and females. There was no correlation between exhaled [H2O2] and age or lung function. Repeated [H2O2] measurements on 2 consecutive days showed satisfactory within-subject reproducibility and [H2O2] in stored samples remained stable for at least 1 month at -20 degrees C. In conclusion, this study provides reference data for exhaled hydrogen peroxide in a large group of healthy children. The observed levels were lower than those reported previously for healthy adults and were independent of age, sex and lung function.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9727806     DOI: 10.1183/09031936.98.12020483

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  7 in total

1.  Measured Pulmonary and Systemic Markers of Inflammation and Oxidative Stress Following Wildland Firefighter Simulations.

Authors:  Matthew D Ferguson; Erin O Semmens; Charles Dumke; John C Quindry; Tony J Ward
Journal:  J Occup Environ Med       Date:  2016-04       Impact factor: 2.162

Review 2.  Noninvasive monitoring of glucose levels: is exhaled breath the answer?

Authors:  Kiera Roberts; Adam Jaffe; Charles Verge; Paul S Thomas
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

Review 3.  Noninvasive effects measurements for air pollution human studies: methods, analysis, and implications.

Authors:  Jaime Mirowsky; Terry Gordon
Journal:  J Expo Sci Environ Epidemiol       Date:  2015-01-21       Impact factor: 5.563

4.  Bordetella bronchiseptica responses to physiological reactive nitrogen and oxygen stresses.

Authors:  Anders Omsland; Katrina M Miranda; Richard L Friedman; Scott Boitano
Journal:  FEMS Microbiol Lett       Date:  2008-05-06       Impact factor: 2.742

5.  Hydrogen peroxide in breath condensate during a common cold.

Authors:  R Q Jöbsis; S L Schellekens; A Fakkel-Kroesbergen; R H Raatgeep; J C de Jongste
Journal:  Mediators Inflamm       Date:  2001-12       Impact factor: 4.711

Review 6.  Exhaled breath condensate--from an analytical point of view.

Authors:  Slavica Dodig; Ivana Cepelak
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

7.  Bedside breath tests in children with abdominal pain: a prospective pilot feasibility study.

Authors:  David C Wong; Samuel D Relton; Victoria Lane; Mohamed Ismail; Victoria Goss; Jane Bytheway; Robert M West; Jim Deuchars; Jonathan Sutcliffe
Journal:  Pilot Feasibility Stud       Date:  2019-11-05
  7 in total