Literature DB >> 9727697

Specific considerations with the automatic implantable atrial defibrillator.

W Jung1, C Wolpert, B Esmailzadeh, S Spehl, S Herwig, B Schumacher, T Lewalter, H Omran, P G Kirchhoff, B Lüderitz.   

Abstract

INTRODUCTION: Internal atrial defibrillation has been evaluated as an alternative approach to the external technique for more than two decades. Previous studies in animals and humans have shown that internal atrial defibrillation is feasible with relatively low energies. The promising results achieved with internal atrial defibrillation have facilitated the development of an implantable atrial defibrillator (IAD). METHODS AND
RESULTS: For any new therapy, it is imperative to demonstrate safety, efficacy, tolerability with improvement in quality of life, and cost-effectiveness compared with therapeutic options already available. Maintenance of sinus rhythm or prolonged duration in arrhythmia-free intervals should be demonstrated clearly with an IAD. Initial clinical experience with the Metrix system indicates stable atrial defibrillation thresholds, appropriate R wave synchronization markers, no shock-induced ventricular proarrhythmia, and excellent detection of atrial fibrillation (AF) with a specificity of 100%. Ventricular proarrhythmia has not been reported for correctly R wave synchronized low-energy shocks when closely coupled to RR intervals, and long-short cycles are avoided.
CONCLUSION: Preliminary experience with the Metrix system suggests that the IAD may offer a therapeutic alternative for a subgroup of patients with drug-refractory, symptomatic, long-lasting, and infrequent episodes of AF. Further efforts must be undertaken to reduce the patient discomfort associated with internal atrial defibrillation in an attempt to make this new therapy acceptable to a larger patient population with AF.

Entities:  

Mesh:

Year:  1998        PMID: 9727697

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  3 in total

Review 1.  [Cardiology update. I: Electrophysiology].

Authors:  P Weismüller; H J Trappe
Journal:  Med Klin (Munich)       Date:  1999-01-15

Review 2.  Clinical experience with implantable atrial and combined atrioventricular defibrillators.

Authors:  W Jung; C Wolpert; B Esmailzadeh; S Spehl; S Herwig; B Schumacher; T Lewalter; H Omran; R Schimpf; C Vahlhaus; A Welz; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 3.  [Atrial defibrillator].

Authors:  W Jung; B Lüderitz
Journal:  Herz       Date:  1998-06       Impact factor: 1.443

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.