Literature DB >> 9725588

Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation.

K L Pasma1, M Kroonwijk, J C de Boer, A G Visser, B J Heijmen.   

Abstract

Measuring portal dose with an electronic portal imaging device (EPID) in external beam radiotherapy can be used to perform routine dosimetric quality control checks on linear accelerators and to verify treatments (in vivo dosimetry). An accurate method to measure portal dose images (PDIs) with a commercially available fluoroscopic EPID has been developed. The method accounts for (i) the optical 'cross talk' within the EPID structure, (ii) the spatially nonuniform EPID response and (iii) the nonlinearity of the EPID response. The method is based on a deconvolution algorithm. Measurement of the required input data is straightforward. The observed nonlinearity of the EPID response was largely due to the somewhat outdated EPID electronics. Nonlinearity corrections for more modern systems are expected to be smaller. The accuracy of the method was assessed by comparing PDIs measured with the EPID with PDIs measured with a scanning ionization chamber in a miniphantom, located at the same position as the fluorescent screen. For irradiations in open, wedged and intensity modulated 25 MV photon beams (produced with dynamic multileaf collimation) EPID and ionization chamber measurements agreed to within 1% (1 SD).

Entities:  

Mesh:

Year:  1998        PMID: 9725588     DOI: 10.1088/0031-9155/43/8/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Verification of MLC based real-time tumor tracking using an electronic portal imaging device.

Authors:  Sarah Han-Oh; Byong Yong Yi; Fritz Lerma; Barry L Berman; Minzhi Gui; Cedric Yu
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Feasibility of using two-dimensional array dosimeter for in vivo dose reconstruction via transit dosimetry.

Authors:  Heeteak Chung; Jonathan Li; Sanjiv Samant
Journal:  J Appl Clin Med Phys       Date:  2011-04-08       Impact factor: 2.102

3.  Intensity-modulated radiation therapy dose verification using fluence and portal imaging device.

Authors:  Iori Sumida; Hajime Yamaguchi; Indra J Das; Hisao Kizaki; Keiko Aboshi; Mari Tsujii; Yuji Yamada; Osamu Suzuki; Yuji Seo; Fumiaki Isohashi; Kazuhiko Ogawa
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

4.  Verification of dynamic and segmental IMRT delivery by dynamic log file analysis.

Authors:  Dale W Litzenberg; Jean M Moran; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

5.  Portal dosimetry in wedged beams.

Authors:  Hanno Spreeuw; Roel Rozendaal; Priscilla Camargo; Anton Mans; Markus Wendling; Igor Olaciregui-Ruiz; Jan-Jakob Sonke; Marcel Van Herk; Ben Mijnheer
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

6.  An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm.

Authors:  Hashemi S M; Bahreyni M H; Mohammadi M; Nasseri S; Bayani S; Gholamhosseinian H; Salek R; Shahedi F; Momennezhad M
Journal:  J Biomed Phys Eng       Date:  2019-10-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.