Literature DB >> 9722098

A retrospective study of combined fixed-removable reconstructions with their analysis of failures.

S P Studer1, C Mäder, W Stahel, P Schärer.   

Abstract

The survival rate and the reasons for failures of 130 combined fixed-removable reconstructions (CFR), incorporated in 112 patients, were assessed. Each CFR reconstruction was classified depending on its attachments: 76 reconstructions were attached with rigid, precise attachments, and constituted the rigid group; 54 reconstructions were attached with either semi-precision or individual attachments and were defined as the semi-rigid group. Of the 130 reconstructions, 41 were determined as complete successes, 39 as partial successes and 50 as failures, leading to 37 major repairs and to 13 new reconstructions. Three reconstructions failed due to technical reasons, 36 due to biological reasons and for 11 reconstructions, both categories of reasons were responsible for their failure. In total, technical reasons were counted 15 times in comparison to 73 biological reasons for those 50 failed reconstruction, with 29 fractured abutment teeth as the most common biological reason. Within the rigid group, 45 failed reconstructions were observed, whereas within the semi rigid group only 5 failures occurred, leading to an 8-year survival estimate (+/- SD) of 30.1% (+/- 6.9%) for the rigid group and 93.1% (+/- 3.9%) for the semi rigid group. Beside the attachment type, the anatomy of the partially edentulous tooth arch in form of the free-end situation and the dentate opposing jaw were identified as risk factors.

Entities:  

Mesh:

Year:  1998        PMID: 9722098     DOI: 10.1046/j.1365-2842.1998.00294.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  4 in total

1.  Biological complications of removable dental prostheses in the moderately reduced dentition: a systematic literature review.

Authors:  Ovidiu Moldovan; Heike Rudolph; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2018-06-29       Impact factor: 3.573

2.  Are implants more reliable than severely compromised endodontically treated teeth as abutments for zirconia-based FPDs? : In vitro results of long-term preclinical load simulation.

Authors:  M Naumann; C Hohmann; A Happe; F Beuer; R Frankenberger; R Seemann; M Rosentritt
Journal:  Clin Oral Investig       Date:  2012-10-27       Impact factor: 3.573

3.  Can We Predict Usage of Dental Services? An Analysis from Germany 2000 to 2015.

Authors:  F Schwendicke; J Krois; R Jordan
Journal:  JDR Clin Trans Res       Date:  2020-02-05

4.  Relevance of variations in the opposing dentition for the functionality of fixed and removable partial dentures: a systematic review.

Authors:  Bernhard Pommer; Martin Krainhöfner; Georg Watzek; Gabor Tepper; Charalabos-Markos Dintsios
Journal:  Int J Dent       Date:  2012-11-04
  4 in total