Literature DB >> 9715456

Ilizarov external fixation in the management of bilateral, highly complex blast injuries of lower extremities: a report of two cases.

A Lerner1, G Nierenberg, H Stein.   

Abstract

Because of their complexity, war injuries inflicted by a blast mechanism often require tailoring of treatment to attain a more individualized solution. We report two cases of bilateral, severely mangled lower limbs with open tibial fractures and crush injuries to the feet. In each case, one limb had to be amputated below the knee, but the other limb was saved by immediate stabilization in a tubular external fixation frame crossing the knee; the frame was later replaced by a hybrid ring fixation frame with a freely moving knee. Such incidences are rare, and the particular management detailed here has not previously been reported in the literature.

Entities:  

Mesh:

Year:  1998        PMID: 9715456     DOI: 10.1097/00005131-199808000-00016

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  2 in total

1.  Mathematical modeling of fixation of a bone fragment in a new Double-needle external Fixator compared to hoffmann ii fixator.

Authors:  M Pitkin; Y Shukeylo; A Gritsanov
Journal:  Ser Biomech       Date:  2007-12

2.  Calcanisation of tibia using Ilizarov fixator in crush injuries of hindfoot: a new method.

Authors:  Mussa Wardak; Emal Wardak; Akshay Goel
Journal:  Int Orthop       Date:  2007-07-17       Impact factor: 3.075