Literature DB >> 9710355

Cessation of insulin infusion at night-time during CSII-therapy: comparison of regular human insulin and insulin lispro.

A Reichel1, H Rietzsch, H J Köhler, A Pfützner, U Gudat, J Schulze.   

Abstract

Development of hyperglycemia with subsequent ketoacidosis is one of the potential risks of a sudden cessation of insulin delivery during continuous insulin infusion therapy with insulin pumps in patients with IDDM. To evaluate differences in the development of ketoacidosis after a sudden pump stoppage between regular human insulin and insulin lispro, we performed an open label randomized crossover investigation with 7 patients (6 male/1 female, mean age (SD: 40.9 +/- 12.9 years). At 10 p.m., 4 hours after a light dinner with a preprandial injection of the corresponding insulin, the catheter was pulled out of the skin. During the observation period, blood glucose (every hour), pH-values and base excess values (every two hours) were measured until 7 a.m. One patient, in the insulin lispro treatment arm, discontinued because early interruption criteria were met after 7 hours. With insulin lispro, the metabolic changes developed 1.5 to 2 hours earlier than with regular human insulin (after 3 hours: difference in base excess (BE) mean +/- SD: regular human insulin: -0.41 +/- 1.04 mmol/l; insulin lispro: -1.69 +/- 0.83 mmol/l, p < 0.05; blood glucose: regular human insulin: 4.93 +/- 2.87 mmol/l, insulin lispro: 8.97 +/- 3.48, p < 0.05; pH values: regular human insulin: 7.38 +/- 0.02, insulin lispro: 7.36 +/- 0.02, n.s.). In general, metabolic deterioration tended to be more pronounced with insulin lispro than with regular human insulin (deltaBE after 7 h: regular human insulin: -2.39 +/- 1.30 mmol/l; insulin lispro: -3.27 +/- 2.43 mmol/l, n.s.). In conclusion, if patients want to be treated with insulin lispro in an insulin pump, they have to be well-educated about the pharmacokinetic properties of the insulin analogue and about the possibility that ketoacidotic deterioration after an interruption of the insulin delivery may occur earlier in comparison to regular human insulin. It is anyway recommendable to perform a pump stop test when starting CSII-treatment in patients with diabetes mellitus.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9710355     DOI: 10.1055/s-0029-1211971

Source DB:  PubMed          Journal:  Exp Clin Endocrinol Diabetes        ISSN: 0947-7349            Impact factor:   2.949


  4 in total

1.  Occlusion Detection Time in Insulin Pumps at Two Different Basal Rates.

Authors:  Guido Freckmann; Ulrike Kamecke; Delia Waldenmaier; Cornelia Haug; Ralph Ziegler
Journal:  J Diabetes Sci Technol       Date:  2017-12-29

2.  Changes in basal insulin infusion rates with subcutaneous insulin infusion: time until a change in metabolic effect is induced in patients with type 1 diabetes.

Authors:  Lutz Heinemann; Leszek Nosek; Christoph Kapitza; Matthias-Axel Schweitzer; Lars Krinelke
Journal:  Diabetes Care       Date:  2009-06-01       Impact factor: 19.112

3.  Comparison of Efficacy and Safety of Lispro and Aspart Evaluated by Continuous Glucose Monitoring System in Patients with Newly Diagnosed Type 2 Diabetes.

Authors:  Bing-Li Liu; Guo-Ping Yin; Feng-Fei Li; Yun Hu; Jin-Dan Wu; Mao-Yuan Chen; Lei Ye; Xiao-Fei Su; Jian-Hua Ma
Journal:  Int J Endocrinol       Date:  2018-03-26       Impact factor: 3.257

4.  New technologies for diabetes: a review of the present and the future.

Authors:  Neesha Ramchandani; Rubina A Heptulla
Journal:  Int J Pediatr Endocrinol       Date:  2012-10-26
  4 in total