UNLABELLED: The efficacy of 99mTc-tetrofosmin for the detection of parathyroid lesions was investigated prospectively in patients with hyperparathyroidism referred for surgical treatment.
METHODS: Twenty-seven patients with primary and 18 with tertiary hyperparathyroidism were studied. Twelve patients had undergone one or more previous neck explorations. Static imaging with 201Tl was performed first, immediately followed by a 30-min 99mTc-tetrofosmin dynamic study. Delayed views of up to 3 hr postinjection were also obtained. Technetium-99m-pertechnetate was used for thyroid delineation. The tetrofosmin/99mTc-pertechnetate subtraction scan (TF/TC), the single-tracer washout technique and the thallium/technetium subtraction (TL/TC) were compared. Quantification of relative uptakes of tracers in the thyroid and abnormal parathyroids was accomplished by measuring activity within regions of interest. Kinetics of tetrofosmin in the thyroid and abnormal parathyroids were studied by evaluating the plots of the parathyroid to thyroid ratios against time as well as by calculation of the half-clearance times from the slow component of the time-activity curves.
RESULTS: The overall sensitivity, specificity and accuracy of TF/TC and TL/TC were 76%, 92% and 83% and 52%, 85% and 65%, respectively. The respective sensitivities were 87% and 70% for adenomas and 72% and 46% for hyperplasia. The parathyroid-to-thyroid activity ratios of tetrofosmin were significantly higher than those of thallium (p < 0.001). The tetrofosmin single-tracer washout study was less accurate than the subtraction technique (overall sensitivity and specificity, 70% and 69%, respectively). The washout properties of tetrofosmin in abnormal parathyroids were not substantially different from those in the thyroid, with a few exceptions (p = 0.4). No correlation of half-clearance times with parathyroid size, degree of early uptake, parathyroid hormone levels or histology could be established. Comparing adenomas to hyperplasia in respect to tetrofosmin retention, a statistically significant difference was observed (p = 0.005).
CONCLUSION: Technetium-99m-tetrofosmin is suitable for parathyroid imaging. The kinetic properties of this agent in parathyroid and thyroid tissues do not warrant differential washout protocols. The diagnostic impact of the observed difference in tetrofosmin kinetics between parathyroid adenomas and hyperplasia requires further investigation.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9708523

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  2 in total

1.  The EANM practice guidelines for parathyroid imaging.

Authors:  Petra Petranović Ovčariček; Luca Giovanella; Ignasi Carrió Gasset; Elif Hindié; Martin W Huellner; Markus Luster; Arnoldo Piccardo; Theresia Weber; Jean-Noël Talbot; Frederik Anton Verburg
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-04-10       Impact factor: 9.236

2.  Primary hyperparathyroidism: imaging to pathology.

Authors:  Sara Piciucchi; Domenico Barone; Giampaolo Gavelli; Alessandra Dubini; Devil Oboldi; Federica Matteuci
Journal:  J Clin Imaging Sci       Date:  2012-10-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.