Literature DB >> 9707200

Accuracy of ICD-9-CM coding for the identification of patients with acute ischemic stroke: effect of modifier codes.

L B Goldstein1.   

Abstract

BACKGROUND AND
PURPOSE: Discharge ICD-9-CM (International Classification of Diseases, 9th Revision, Clinical Modification) codes have been used to identify patients with acute stroke for epidemiological, quality of care, and cost studies. The aim of this study was to determine if the accuracy of the primary ICD-9-CM codes for ischemic stroke is improved by modifier codes and how specific codes reflect stroke subtype diagnoses.
METHODS: Available hospital charts for all patients discharged from a single hospital between May 1995 and June 1997 with ICD-9-CM codes 433 (occlusion and stenosis of precerebral arteries), 434 (occlusion of cerebral arteries), or 436 (acute but ill-defined cerebrovascular disease) listed in the first position were reviewed. The primary discharge diagnosis was verified, and a presumed stroke subtype was assigned on the basis of information provided in the medical record.
RESULTS: Charts were available for 175 of the 198 identified patients (88%). Of these, 61% had an acute ischemic stroke (code 433, 4%; 434, 82%; 436, 79%) with the remaining patients having other conditions. Of the 130 patients with a modifier code indicating cerebral infarction, 79% had an acute stroke; of the 45 patients with a modifier code indicating an absence of cerebral infarction, 7% had acute stroke (sensitivity, 0.97; specificity, 0.60). The codes with the highest proportions of ischemic stroke cases were 434.11 (embolic occlusion of cerebral arteries with infarction, 85%), 434.91 (unspecified occlusion of precerebral arteries with infarction, 82%), and 436 (79%), with a combined sensitivity of 0.81 and specificity of 0.90. On review, 73% of patients with code 434.11 had embolic strokes, and 47% of those with code 436 had an identified stroke cause. Of patients with code 434.91, 39% had stroke of uncertain cause, 25% "lacunar," 17% atherothrombosis, and 15% embolism.
CONCLUSIONS: Despite the use of modifier codes, 15% to 20% of patients with the indicated primary ICD-9-CM codes have conditions other than acute ischemic stroke. Although the proportion of patients with acute stroke increased from 61% to 79% with the use of modifier codes, the inclusion of modifier codes did not have an appreciable effect on the accuracy of the coding if patients with code 433 are excluded. Assignment of presumed ischemic stroke subtype is particularly inaccurate.

Entities:  

Mesh:

Year:  1998        PMID: 9707200     DOI: 10.1161/01.str.29.8.1602

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  143 in total

1.  On the trail of necrotizing fasciitis in children.

Authors:  J Ray
Journal:  CMAJ       Date:  2001-01-23       Impact factor: 8.262

2.  Deaths from stroke in US young adults, 1989-2009.

Authors:  Sharon N Poisson; David Glidden; S Claiborne Johnston; Heather J Fullerton
Journal:  Neurology       Date:  2014-10-31       Impact factor: 9.910

3.  Effectiveness and safety of warfarin initiation in older hemodialysis patients with incident atrial fibrillation.

Authors:  Wolfgang C Winkelmayer; Jun Liu; Soko Setoguchi; Niteesh K Choudhry
Journal:  Clin J Am Soc Nephrol       Date:  2011-09-29       Impact factor: 8.237

4.  Elevation of blood urea nitrogen is predictive of long-term mortality in critically ill patients independent of "normal" creatinine.

Authors:  Kevin Beier; Sabitha Eppanapally; Heidi S Bazick; Domingo Chang; Karthik Mahadevappa; Fiona K Gibbons; Kenneth B Christopher
Journal:  Crit Care Med       Date:  2011-02       Impact factor: 7.598

5.  Did the introduction of a prospective payment system for nursing home stays reduce the likelihood of pharmacological management of secondary ischaemic stroke?

Authors:  Kate L Lapane; Carmel M Hughes
Journal:  Drugs Aging       Date:  2006       Impact factor: 3.923

6.  Variation in do-not-resuscitate orders for patients with ischemic stroke: implications for national hospital comparisons.

Authors:  Adam G Kelly; Darin B Zahuranec; Robert G Holloway; Lewis B Morgenstern; James F Burke
Journal:  Stroke       Date:  2014-02-12       Impact factor: 7.914

7.  Comparison of Medicare claims versus physician adjudication for identifying stroke outcomes in the Women's Health Initiative.

Authors:  Kamakshi Lakshminarayan; Joseph C Larson; Beth Virnig; Candace Fuller; Norrina Bai Allen; Marian Limacher; Wolfgang C Winkelmayer; Monika M Safford; Dale R Burwen
Journal:  Stroke       Date:  2014-02-13       Impact factor: 7.914

8.  Discovering medical conditions associated with periodontitis using linked electronic health records.

Authors:  Mary Regina Boland; George Hripcsak; David J Albers; Ying Wei; Adam B Wilcox; Jin Wei; Jianhua Li; Steven Lin; Michael Breene; Ronnie Myers; John Zimmerman; Panos N Papapanou; Chunhua Weng
Journal:  J Clin Periodontol       Date:  2013-03-15       Impact factor: 8.728

9.  Accuracy of administrative data versus clinical data to evaluate carotid endarterectomy and carotid stenting.

Authors:  Rodney P Bensley; Shunsuke Yoshida; Ruby C Lo; Margriet Fokkema; Allen D Hamdan; Mark C Wyers; Elliot L Chaikof; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2013-03-13       Impact factor: 4.268

10.  Hub-and-spoke stroke network in the Veneto region: a retrospective study investigating the effectiveness of the stroke pathway and trends over time.

Authors:  L Nardetto; B Giometto; G Moretto; D Mantoan; M Saia
Journal:  Neurol Sci       Date:  2017-09-13       Impact factor: 3.307

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.