Literature DB >> 9704323

Graft-tunnel mismatch in endoscopic anterior cruciate ligament reconstruction. Intraoperative and cadaver measurement of the intra-articular graft length and the length of the patellar tendon.

M Denti1, M Bigoni, P Randelli, M Monteleone, A Cevenini, A Ghezzi, A Schiavone Panni, C Trevisan.   

Abstract

The results of a study conducted on 50 knees endoscopically reconstructed for an anterior cruciate ligament (ACL) lesion with a free bone-patellar tendon-bone graft and 9 cadaver knees are reported. The mean lengths of the patellar tendon (45.48 +/- 4.71 mm) and intra-articular ACL graft (20.44 +/- 1.98 mm) were measured in the operated knees. The mean length of the tibial bone tunnel (51.62 +/- 2.60 mm) was also measured with a tibial guide at 55 degrees. No statistically significant correlation was found between these three measurements. The length of the patellar tendon was weakly correlated with body height. Measurement of the tibial tunnel on the cadaver knees with increasing degrees of inclination revealed a mean length increase of 0.68 mm per degree (confidence limits: 0.49-0.86). Comparison between the tunnel lengths obtained with the guide and those measured with a Kirschner wire showed a mean difference of 2.3 mm. It is thus desirable to make the tunnel about 53 mm long to ensure excellent fixation of a 28 mm bone block with a 25 mm interference screw. Correct measurement of the anatomical structures involved is in any event an essential requirement for proper execution of the surgical technique.

Entities:  

Mesh:

Year:  1998        PMID: 9704323     DOI: 10.1007/s001670050093

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  14 in total

1.  Anatomic anterior cruciate ligament reconstruction: the two-incision technique.

Authors:  Raffaele Garofalo; Elyazid Mouhsine; Pierre Chambat; Olivier Siegrist
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-01-04       Impact factor: 4.342

2.  The geometry of patella and patellar tendon measured on knee MRI.

Authors:  Jae Ho Yoo; Seung Rim Yi; Jin Hong Kim
Journal:  Surg Radiol Anat       Date:  2007-09-26       Impact factor: 1.246

3.  Avoiding graft-tunnel length mismatch in anterior cruciate ligament reconstruction: the single-bone plug technique.

Authors:  Brian Grawe; Amber Smerina; Answorth Allen
Journal:  Arthrosc Tech       Date:  2014-06-23

4.  The biomechanical effects of graft rotation on ACL reconstruction tunnel mismatch.

Authors:  Danilo Ricardo Okiishi de Oliveira; Eduardo Takahashi Garcia; Fernando Augusto Freitas Fuso; Cesar Augusto Martins Pereira; Marco Martins Lages; Adriano Marques de Almeida; Tiago Lazzaretti Fernandes; André Pedrinelli; Arnaldo José Hernandez
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-03-29       Impact factor: 4.342

5.  Influence of the bone block position on the tunnel enlargement in ACL reconstruction.

Authors:  Dominik J Hoigne; Peter M Ballmer
Journal:  Orthop Rev (Pavia)       Date:  2010-03-20

6.  Is There Any Correlation Between Patient Height and Patellar Tendon Length?

Authors:  Amir M Navali; Mohammad Asghari Jafarabadi
Journal:  Arch Bone Jt Surg       Date:  2015-04

7.  Graft-Tunnel Mismatch in Endoscopic ACL Reconstruction: Reliability of Measuring Tunnel Lengths and Intra-articular Distance.

Authors:  Tim Dwyer; Lucas Bristow; Nicholas Bayley; Ujash Sheth; Jihad Abouali; M Lucas Murnaghan; David Wasserstein; Darrell Ogilvie-Harris; Ben Fine; John Theodoropoulos; Jaskarndip Chahal
Journal:  Orthop J Sports Med       Date:  2018-12-21

8.  Measurement of normal patellar ligament and anterior cruciate ligament by MRI and data analysis.

Authors:  Hongpo Wang; Caihong Hua; Hongkai Cui; Yuxia Li; Haixia Qin; Dongming Han; Junyan Yue; Changhua Liang; Ruimin Yang
Journal:  Exp Ther Med       Date:  2013-01-17       Impact factor: 2.447

9.  Femoral tunnel placement in anterior cruciate ligament reconstruction: rationale of the two incision technique.

Authors:  Raffaele Garofalo; Biagio Moretti; Cyril Kombot; Lorenzo Moretti; Elyazid Mouhsine
Journal:  J Orthop Surg Res       Date:  2007-05-21       Impact factor: 2.359

10.  How to Avoid Graft-Tunnel Length Mismatch in Modified Transtibial Technique for Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Graft.

Authors:  Dukhwan Ko; Hyeung-June Kim; Seong-Hak Oh; Byung-June Kim; Sung-Jae Kim
Journal:  Clin Orthop Surg       Date:  2018-11-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.