Literature DB >> 9703040

False-response monitoring during automated perimetry.

A J Vingrys1, S Demirel.   

Abstract

PURPOSE: To ascertain the accuracy and precision of the catch-trial monitor used to estimate the false-response rate in automated perimetry.
METHODS: False responses were automatically injected at various rates by modified perimetric software while reliable perimetric subjects underwent visual field thresholding. Four repeat tests were conducted within a 1-hour period to quantify the variability and bias inherent in the catch-trial technique.
RESULTS: The catch-trial method gave a very accurate estimate of the average false-response rate. Precision, however, was quite poor because of the small sample of catch trials. Outcomes were predicted using a binomial model, and we demonstrated good concordance between the model and empirical data. When the true false-response rate was 33%, estimates derived from catch trials ranged from 7 to 57%.
CONCLUSIONS: Although the catch-trial method gave an accurate estimate of the false-response rate, confidence intervals were too wide to provide a high level of precision. Our data suggest that tests with reported false-response rates < 20% may be considered reliable.

Mesh:

Year:  1998        PMID: 9703040     DOI: 10.1097/00006324-199807000-00020

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  6 in total

Review 1.  The definition and classification of glaucoma in prevalence surveys.

Authors:  Paul J Foster; Ralf Buhrmann; Harry A Quigley; Gordon J Johnson
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

2.  Structure-function correlations using scanning laser polarimetry in primary angle-closure glaucoma and primary open-angle glaucoma.

Authors:  Pei-Jung Lee; Catherine Jui-Ling Liu; Robert Wojciechowski; Joan E Bailey-Wilson; Ching-Yu Cheng
Journal:  Am J Ophthalmol       Date:  2010-03-04       Impact factor: 5.258

3.  Quantifying biomarkers of axonal degeneration in early glaucoma to find the disc at risk.

Authors:  R L Bartlett; B E Frost; K E Mortlock; J R Fergusson; N White; J E Morgan; R V North; J Albon
Journal:  Sci Rep       Date:  2022-06-07       Impact factor: 4.996

4.  Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field.

Authors:  Peter Essig; Yannick Sauer; Siegfried Wahl
Journal:  Transl Vis Sci Technol       Date:  2022-05-02       Impact factor: 3.048

5.  A Comparison of Perimetric Results from a Tablet Perimeter and Humphrey Field Analyzer in Glaucoma Patients.

Authors:  Yu Xiang George Kong; Mingguang He; Jonathan G Crowston; Algis J Vingrys
Journal:  Transl Vis Sci Technol       Date:  2016-11-03       Impact factor: 3.283

6.  Gaze tracker parameters have little association with visual field metrics of intrasession frontloaded SITA-Faster 24-2 visual field results.

Authors:  Jack Phu; Michael Kalloniatis
Journal:  Ophthalmic Physiol Opt       Date:  2022-05-22       Impact factor: 3.992

  6 in total