Literature DB >> 9702892

Assessment of coronary artery patency after stent placement using magnetic resonance angiography.

A J Duerinckx1, D Atkinson, R Hurwitz.   

Abstract

The ability to noninvasively assess the patency of coronary stents would represent a significant advance. We evaluated the safety and ability of two-dimensional coronary MR angiography in imaging stents and suggesting patency. Coronary MR angiography of 26 coronary stents (Palmaz-Schatz) was performed in 16 patients 39 to 73 years of age. Studies were performed between 2 and 4 months after stent placement. All patients were symptom free at the time of imaging. Coronary MR angiography was performed with a commercial 1.5-T MR imager using an electrocardiographically gated pulse sequence with breath-holding. Images were obtained in mid-diastole with and without fat suppression. Image artifacts caused by the metal in the stents were clearly visualized in all 26 stents (100% sensitivity for stent detection). Arterial flow signal was seen in the coronary artery or graft distal to the stent in 25 of 26 cases (96%). All patients, except for the one in which distal flow could not be seen, remained symptom free for >2 years. The distribution of stent locations was as follows: 10 in the right coronary artery (RCA), 10 in the left anterior descending coronary artery (LAD), 2 in the left circumflex coronary artery, and 4 in saphenous vein grafts (SVGs) to RCA. One patient had 2 RCA and 2 LAD stents, one had 3 RCA and 1 LAD stents, one had 3 SVG stents, and two had double RCA stents. Coronary MR angiography is safe for noninvasive imaging of coronary stents, and in the proper clinical setting, it can be used to help suggest patency.

Entities:  

Mesh:

Year:  1998        PMID: 9702892     DOI: 10.1002/jmri.1880080420

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

Review 1.  Coronary MR angiography.

Authors:  A J Duerinckx
Journal:  Int J Cardiovasc Imaging       Date:  2001-12       Impact factor: 2.357

Review 2.  2014 Korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the Korean Society of Cardiology and the Korean Society of Radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

Review 3.  2014 korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the korean society of cardiology and the korean society of radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean Circ J       Date:  2014-11-25       Impact factor: 3.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.