Measurement of volatile organic compounds by the US Environmental Protection Agency Compendium Method TO-17. Evaluation of performance criteria.

W A McClenny1, M Colón.   

Abstract

An evaluation of performance criteria for US Environmental Protection Agency Compendium Method TO-17 for monitoring volatile organic compounds (VOCs) in air has been accomplished. The method is a solid adsorbent-based sampling and analytical procedure including performance criteria for four merit parameters. These are: (1) the method detection limit (MDL); (2) the method precision; (3) the agreement between two samples taken at different flow-rates over the same time period [a distributed volume pair (DVP)]; and (4) audit accuracy. A two-adsorbent tube packing of Carbotrap and Carboxen 1000 (Supelco) was tested. Synthetic mixtures containing 41 compounds at concentrations of 10 ppb (v/v) or 2 ppb (v/v) each in humidified zero air, and indoor air from a personal residence, were sampled for 1-h periods during which 1-l and 4-l samples were obtained simultaneously. For synthetic samples, the MDL was determined to be < or = 0.5 ppb (v/v) for 29 of the 41 compounds examined for samples at 47% relative humidity (RH), and for 27 of 41 compounds at 85% RH. The method precision at both 2 and 10 ppb (v/v) was < or = 20% for 90+ % of the samples using five sampling runs and the DVP samples were within 25% for 80% of the samples. For the indoor samples, 26 target compounds were tentatively identified and 12 unknowns were detected; all but 10% of these compounds met the DVP criteria.

Mesh:

Substances:

Year:  1998        PMID: 9697318     DOI: 10.1016/s0021-9673(98)00327-6

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Influence of relative humidity and ozone on the sampling of volatile organic compounds on carbotrap/carbosieve adsorbents.

Authors:  Fabienne Palluau; Philippe Mirabel; Maurice Millet
Journal:  Environ Monit Assess       Date:  2006-08-05       Impact factor: 2.513

2.  Parameters determining the use of zeolite 5A as collector medium in passive flux samplers to estimate N2O emissions from livestock sources.

Authors:  Araceli D Larios; Satinder Kaur Brar; Antonio Avalos Ramírez; Stéphane Godbout; Fabiola Sandoval-Salas; Joahnn H Palacios; Patrick Dubé; Beatriz Delgado; Anne Giroir-Fendler
Journal:  Environ Sci Pollut Res Int       Date:  2017-03-27       Impact factor: 4.223