Literature DB >> 9695144

Lung delivery of salbutamol given by breath activated pressurized aerosol and dry powder inhaler devices.

B J Lipworth1, D J Clark.   

Abstract

Poor inhalation technique is prevalent in asthmatics using standard metered dose inhalers (MDI). Both dry powder inhalers (DPI) and breath activated MDIs offer a solution to this problem. Our aim was to compare the lung delivery of salbutamol from two DPIs, Diskhaler and Diskus (Accuhaler), and the Easi-Breathe breath activated MDI. Ten healthy volunteers mean (SEM) age 24.0 years (1.7) were studied in a randomized single (investigator) blind crossover design. Single 1200 micrograms nominal doses of salbutamol via Diskhaler and Diskus (6 sequential 200 micrograms puffs) and Easi-Breathe (12 sequential 100 micrograms puffs) were given over 6 min. Mouth rinsing was performed after every inhalation sequence. Lung delivery was evaluated by measuring the early lung absorption profile of salbutamol at 5, 10, 15 and 20 min after inhalation, with calculation of peak (Cmax) and average over 20 min (Cav) concentration (ng/ml). Both the Diskhaler and the Easi-Breathe produced significantly greater salbutamol Cmax and Cav than Diskus (as mean and 96% CI for difference vs. Diskus): [Cmax] Diskus 3.22 vs. Diskhaler 4.35 (95% CI 0.19 to 2.08), vs. Easi-Breathe 3.98 (95% CI -0.18 to 1.71). [Cav] Diskus 2.62 vs. Diskhaler 3.95 (95% CI 0.52 to 2.14), vs. Easi-Breathe 3.52 (95% CI 0.09 to 1.71). For Cav this amounted to a 1.51-fold difference (95% CI 1.35 to 1.68) between Diskhaler vs. Diskus, and a 1.36-fold difference (95% CI 1.03 to 1.69) for Easi-Breathe vs. Diskus. In conclusion we found that, in vivo, the Diskus DPI produced significantly lower lung delivery for the same nominal dose of salbutamol than either Diskhaler DPI or the Easi-Breathe pressurised aerosol. This shows that breath activated inhaler devices may have different in vivo deposition characteristics for delivering the same drug.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9695144     DOI: 10.1006/pupt.1997.0093

Source DB:  PubMed          Journal:  Pulm Pharmacol Ther        ISSN: 1094-5539            Impact factor:   3.410


  7 in total

Review 1.  Methods to identify drug deposition in the lungs following inhalation.

Authors:  H Chrystyn
Journal:  Br J Clin Pharmacol       Date:  2001-04       Impact factor: 4.335

Review 2.  Antiasthmatic drug delivery in children.

Authors:  Elizabeth Biggart; Andrew Bush
Journal:  Paediatr Drugs       Date:  2002       Impact factor: 3.022

3.  Pharmacokinetics and systemic beta2-adrenoceptor-mediated responses to inhaled salbutamol.

Authors:  S J Fowler; B J Lipworth
Journal:  Br J Clin Pharmacol       Date:  2001-04       Impact factor: 4.335

Review 4.  Once-daily inhaled corticosteroids in children with asthma: dry powder inhalers.

Authors:  C Möller
Journal:  Drugs       Date:  1999       Impact factor: 9.546

5.  Investigation into alternative sugars as potential carriers for dry powder formulation of budesonide.

Authors:  Mohammed-Nurul Momin; Atoosa Hedayati; Ali Nokhodchi
Journal:  Bioimpacts       Date:  2011-08-05

Review 6.  Are inhaled systemic therapies a viable option for the treatment of the elderly patient?

Authors:  Stephen Allen
Journal:  Drugs Aging       Date:  2008       Impact factor: 3.923

7.  The challenge of delivering therapeutic aerosols to asthma patients.

Authors:  Federico Lavorini
Journal:  ISRN Allergy       Date:  2013-08-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.