Literature DB >> 9692525

Regional mean systolic myocardial velocity estimation by real-time color Doppler myocardial imaging: a new technique for quantifying regional systolic function.

U M Wilkenshoff1, A Sovany, L Wigström, B Olstad, L Lindström, J Engvall, B Janerot-Sjöberg, B Wranne, L Hatle, G R Sutherland.   

Abstract

A new color Doppler myocardial imaging (CDMI) system with high spatial and temporal resolution and novel postprocessing modalities has been developed that could allow quantifiable stress echocardiography. The purpose of this study was to determine whether regional myocardial systolic velocities could be accurately and reproducibly measured both at rest and during bicycle ergometry by using CDMI. Thirty normal subjects were examined with CDMI at rest, and peak mean systolic myocardial velocities (MSV) were measured for 34 predetermined left ventricular myocardial segments. Interobserver variability and intraobserver variability were established for all segments. Submaximal bicycle ergometry was performed in 20 normal subjects by using standardized weight-related increases in workload. MSV were measured at each step of exercise for 16 left ventricular stress echo segments. At rest, a base-apex gradient in regional MSV was recorded with highest longitudinal shortening velocities at the base. A similar pattern was noted for circumferential shortening MSV. Measurements were predictable and highly reproducible with low interobserver and intraobserver variability for 26 of 34 segments. Reproducibility was poor for basal anteroseptal segments in all views and mid anterior, anteroseptal, and septal segments in the short-axis views. During exercise, mid and basal segments of all walls showed a significant increase of MSV between each workload step and for apical segments between alternate steps. The resting base-apex velocity gradient observed at rest remained in all walls throughout ergometry. Thus a CDMI system with improved spatial and temporal resolution and postprocessing analysis modalities provided reproducible and accurate quantification of segmental left ventricular circumferential and longitudinal contraction both at rest and during exercise.

Entities:  

Mesh:

Year:  1998        PMID: 9692525     DOI: 10.1053/je.1998.v11.a90584

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  19 in total

Review 1.  Tissue Doppler imaging: current and potential clinical applications.

Authors:  D J Price; D R Wallbridge; M J Stewart
Journal:  Heart       Date:  2000-11       Impact factor: 5.994

2.  Doppler myocardial imaging in the assessment of normal and ischemic myocardial function--past, present and future.

Authors:  J M Strotmann; L Hatle; G R Sutherland
Journal:  Int J Cardiovasc Imaging       Date:  2001-04       Impact factor: 2.357

3.  Evaluation of left atrial appendage functions in patients with thrombus and spontaneous echo contrast in left atrial appendage by using color Doppler tissue imaging.

Authors:  Ramazan Topsakal; Namik Kemal Eryol; Yüksel Ciçek; Hayrettin Sağlam; Ergün Seyfeli; Adnan Abaci; Abdurrahman Oğuzhan; Ali Ergin; Emrullah Başar
Journal:  Ann Noninvasive Electrocardiol       Date:  2004-10       Impact factor: 1.468

4.  Exercise tissue Doppler echocardiography with strain rate imaging in healthy young individuals: feasibility, normal values and reproducibility.

Authors:  Björn Goebel; Raoul Arnold; Eric Koletzki; Herbert E Ulmer; Joachim Eichhorn; Martin Borggrefe; Hans R Figulla; Tudor C Poerner
Journal:  Int J Cardiovasc Imaging       Date:  2006-07-26       Impact factor: 2.357

Review 5.  Two-Dimensional Strain Imaging: Basic principles and Technical Consideration.

Authors:  Mustafa Kurt; Ibrahim Halil Tanboga; Enbiya Aksakal
Journal:  Eurasian J Med       Date:  2014-06

6.  Echocardiographic assessment of arrhythmogenic right ventricular cardiomyopathy.

Authors:  L Lindström; U M Wilkenshoff; H Larsson; B Wranne
Journal:  Heart       Date:  2001-07       Impact factor: 5.994

7.  Assessment of myocardial function of the systemic right ventricle in patients with D-transposition of the great arteries after atrial switch operation by tissue Doppler echocardiography.

Authors:  A Rentzsch; M Y Abd El Rahman; W Hui; A Helweg; P Ewert; M Gutberlet; P E Lange; F Berger; H Abdul-Khaliq
Journal:  Z Kardiol       Date:  2005-08

8.  Strain rate imaging after dynamic stress provides objective evidence of persistent regional myocardial dysfunction in ischaemic myocardium: regional stunning identified?

Authors:  R I Williams; N Payne; T Phillips; J D'hooge; A G Fraser
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

9.  Clarification on the role of LV untwisting in LV "relaxation" and diastolic filling.

Authors:  T Jake Samuel; Eric J Stöhr
Journal:  Clin Res Cardiol       Date:  2017-08-10       Impact factor: 5.460

10.  Are measurements of systolic myocardial velocities and displacement with colour and spectral Tissue Doppler compatible?

Authors:  Aristomenis Manouras; Arben Shala; Evangelia Nyktari; Kambiz Shahgaldi; Reidar Winter; Panagiotis Vardas; Lars-Ake Brodin; Jacek Nowak
Journal:  Cardiovasc Ultrasound       Date:  2009-06-23       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.