Literature DB >> 9687921

[Normal value of the tracheal bifurcation angle and correlation with left atrial volume].

V Coppola1, G Vallone, E Coscioni, M Coppola, G Maraziti, M Alfinito, G Di Benedetto.   

Abstract

PURPOSE: We evaluated the mean value and the variability range of the tracheal bifurcation angle by patient gender, age, height, weight, build, body area and max transverse diameter of the chest under normal conditions. We also evaluated tracheal bifurcation angle changes in orthostatism and recumbency, as well as in the different respiratory phases. Finally, we investigated the statistical correlation between the tracheal bifurcation angle value and the left atrial volume, to eventually derive either value from the other.
MATERIAL AND METHODS: We reviewed 700 high-voltage radiographs of the chest performed in 500 patients with normal echocardiographic findings from 1986 to 1990. To analyze the relationships with the left atrium, 100 patients with echocardiographically enlarged atrium were submitted to high-voltage radiography. The tracheal bifurcation angle was measured directly.
RESULTS: Mediastinal radiographs nearly always depict the trachea and extraparenchymal bronchi adequately. The tracheal bifurcation angle should be measured continuing and joining the upper and lower parabronchial contours. A 4-degree deviation is accepted between the upper or interbronchial and lower or carinal angles since the angles formed by parallel segments have the same value. Under normal conditions the absolute mean value of the tracheal bifurcation angle was 79.7 degrees and the range 37-105 degrees. DISCUSSION AND
CONCLUSIONS: In normal patients the mean value of the tracheal bifurcation angle: is independent of age and gender; depends on build; is related to the max transverse diameter of the chest and to body area; exhibits no major radiographic changes in orthostatism versus recumbency; exhibits no major radiographic changes in expiration versus inspiration; is correlated with left atrial volume, but the value is not statistically significant.

Entities:  

Mesh:

Year:  1998        PMID: 9687921

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  3 in total

1.  Design and Modelling of a Continuum Robot for Distal Lung Sampling in Mechanically Ventilated Patients in Critical Care.

Authors:  Zisos Mitros; Balint Thamo; Christos Bergeles; Lyndon da Cruz; Kevin Dhaliwal; Mohsen Khadem
Journal:  Front Robot AI       Date:  2021-05-03

2.  Tracheo-bronchial angles in the human fetus -- an anatomical, digital, and statistical study.

Authors:  Marcin Daroszewski; Michał Szpinda; Piotr Flisiński; Anna Szpinda; Alina Woźniak; Adam Kosiński; Marek Grzybiak; Celestyna Mila-Kierzenkowska
Journal:  Med Sci Monit Basic Res       Date:  2013-07-16

3.  3D-measurement of tracheobronchial angles on inspiratory and expiratory chest CT in COPD: respiratory changes and correlation with airflow limitation.

Authors:  Rintaro Onoe; Tsuneo Yamashiro; Hiroshi Handa; Shinya Azagami; Shin Matsuoka; Takeo Inoue; Teruomi Miyazawa; Masamichi Mineshita
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2018-08-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.