Literature DB >> 9684694

Kinetics of 131I-beta2 microglobulin in hemodialysis patients: assessment using total body counting.

J Chanard1, V Caudwell, J Valeire, C Vincent, C Randoux, A Wuillai, A Wynckel.   

Abstract

The kinetics of 131I-beta2-microglobulin (beta2-M) were studied using external total body gamma counting in a low noise chamber after administration of trace doses of radioactivity (4 microCi) in 14 uremic patients treated by either hemodialysis or hemofiltration. Data were collected over a 1 week period that included 3 dialysis sessions. The following artificial membranes were used: Cuprophan, polyacrylonitrile AN69, polysulfone, polymethylmethacrylate (PMMA), and polyamide. Radiolabeled beta2-M excretion by an extrarenal route was nearly nonexistent. The 131I-beta2-M half-life was between 2.4 and 8 days, shorter in patients with residual diuresis. A mean removal of 153+/-33 mg/L of beta2-M was obtained per dialysis session with a highly permeable membrane. A hemofiltration session (25 L exchange per session) was slightly more efficient in removing beta2-M than a 4 h hemodialysis session with the same AN69 highly permeable membrane. The amounts of 131I-beta2-M binding on the membranes, expressed as beta2-M equivalents, were 0, 16, 54, 58, and 59 mg/m2 for Cuprophan, polysulfone, polyacrylonitrile AN69, polyamide, and PMMA, respectively. In conclusion, the decrease of total body gamma counting directly reflected the beta2-M breakdown and removal in hemodialysis patients. Intact beta2-M was removed by convection with synthetic, highly permeable membranes. In addition, membrane adsorption accounted for 15% (polysulfone) to near 100% (PMMA) of the beta2-M removal per session. Adsorption was of the same magnitude regardless of the dialysis technique in use, indicating a membrane saturability process. None of the currently available dialysis procedures based on a 3 sessions per week schedule can balance beta2-M generation.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9684694     DOI: 10.1046/j.1525-1594.1998.06197.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  1 in total

1.  The use of SDS-PAGE scanning of spent dialysate to assess uraemic toxin removal by dialysis.

Authors:  Alain Ficheux; Nathalie Gayrard; Ilan Szwarc; Daniel Andress; Stéphan Soullier; Yohan Duny; Gilles Goubert; Marie Thomas; Johanna Bismuth-Mondolfo; Jean-Pierre Daurès; Philippe Brunet; Marie-Françoise Servel; Angel Argilés
Journal:  Nephrol Dial Transplant       Date:  2010-12-10       Impact factor: 5.992

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.