Literature DB >> 9684380

Capillary electrophoresis/electrospray ionization high mass accuracy time-of-flight mass spectrometry for protein identification using peptide mapping.

P Cao1, M Moini.   

Abstract

Capillary electrophoresis/electrospray ionization (CE/ESI) high mass accuracy time-of-flight mass spectrometry was used for the first time to characterize small proteins using peptide mapping. To identify small proteins, the intact proteins were first analyzed to obtain their average molecular weights with errors less than 1 Da. On-line capillary electrophoresis mass spectrometry of the tryptic digests of these small proteins was then performed to obtain the accurate molecular weights of the peptides with accuracies of approximately 10 ppm. Next, this information was used for the identification of the proteins using a protein database. It was found that high mass accuracy is an effective tool in reducing the list of most-likely proteins generated by the database. In addition, on-line collision-induced dissociation of the completely or partially resolved capillary electrophoresis peaks of the protein digests was used to unambiguously identify the sequences of these peptides. Each CE/ESI-MS analysis used only 5 nL of sample containing approximately 120 fmol of each peptide in protein digests. The results indicate that the combination of capillary electrophoresis and high resolution, high mass accuracy time-of-flight mass spectrometry is a viable option for the identification of small proteins using peptide mapping.

Mesh:

Substances:

Year:  1998        PMID: 9684380     DOI: 10.1002/(SICI)1097-0231(19980715)12:13<864::AID-RCM244>3.0.CO;2-G

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

Review 1.  Mass spectrometry innovations in drug discovery and development.

Authors:  D I Papac; Z Shahrokh
Journal:  Pharm Res       Date:  2001-02       Impact factor: 4.200

2.  A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  J C Hannis; D C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2000-10       Impact factor: 3.109

Review 3.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

4.  Separation and detection of the alpha- and beta-chains of hemoglobin of a single intact red blood cells using capillary electrophoresis/electrospray ionization time-of-flight mass spectrometry.

Authors:  P Cao; M Moini
Journal:  J Am Soc Mass Spectrom       Date:  1999-02       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.