Literature DB >> 9682957

Surface treated large bore catheters with silver based coatings versus untreated catheters for extracorporeal detoxification methods.

R Bambauer1, P Mestres, R Schiel, J M Schneidewind, R Goudjinou, R Latza, R Inniger, S Bambauer, P Sioshansi.   

Abstract

Infection, thrombosis, and stenosis are among the most frequent complications associated with blood contacting catheters. Because these problems are usually related to surface properties of the base catheter material, surface treatment processes, such as ion implantation and ion beam assisted deposition (silver based coatings), can be used to mitigate such complications. Because these ion beam based processes affect only the near-surface region (approximately the outer 1 microm), there is little effect on bulk material properties. This study evaluated silver coated large bore catheters used for extracorporeal detoxification. In a 122 patient prospective study, 156 large bore catheters were inserted into the internal jugular or subclavian veins. Seventy-eight surface treated catheters (SPI-ARGENT, Spire Corporation, Bedford, MA; n = 32 acute catheters, n = 45 long-term catheters) were Bambauer inserted in 55 patients. Seventy-eight untreated catheters placed in 67 patients served as controls (n = 35 acute catheters, n = 43 long-term catheters). After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They were also examined using a scanning electron microscope (SEM). Bacterial colonization was observed in 15.4% of the treated catheters compared with 44.9% of untreated catheters. The SEM investigations showed all treated catheters to possess low thrombogenicity. Results of the study indicate that ion beam based processes can be used to improve thrombus and infection resistance of blood contacting catheters.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9682957     DOI: 10.1097/00002480-199807000-00012

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

Review 1.  Catheter impregnation, coating or bonding for reducing central venous catheter-related infections in adults.

Authors:  Nai Ming Lai; Nathorn Chaiyakunapruk; Nai An Lai; Elizabeth O'Riordan; Wilson Shu Cheng Pau; Sanjay Saint
Journal:  Cochrane Database Syst Rev       Date:  2016-03-16

2.  Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments.

Authors:  Rolf Bambauer; Ralf Schiel; Carolin Bambauer; Reinhard Latza
Journal:  Int J Nephrol       Date:  2012-04-10
  2 in total