Literature DB >> 9681541

Instrumented measurement of the posterolateral corner.

R M Bleday1, G C Fanelli, B F Giannotti, C J Edson, T A Barrett.   

Abstract

A new device called the Lars Rotational Laxiometer (Lars Inc, Dijon, France) is introduced to aid in the diagnosis of posterolateral rotatory instability of the knee. This device assigns a quantitative value for tibial external rotation. Three examiners each evaluated a separate group of 30 different subjects (total 180 knees) to obtain side-to-side differences. The subjects had no history of injury, pain, or instability. An external rotation measurement was performed at 30 degrees and 90 degrees of knee flexion. At 90 degrees, the mean side-to-side difference was 4.4 degrees (range, 3.7 degrees to 5.1 degrees); at 30 degrees it was 5.5 degrees (range, 4.7 degrees to 6.3 degrees). There was no significant difference with gender or age. The purpose of this study is to establish baseline side-to-side values for the posterolateral complex in normal knees. Objective values are obtainable with the Laxiometer.

Entities:  

Mesh:

Year:  1998        PMID: 9681541     DOI: 10.1016/s0749-8063(98)70077-5

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  12 in total

1.  Reliability of the dial test using a handheld inclinometer.

Authors:  David A Krause; Bruce A Levy; Jay P Shah; Michael J Stuart; John H Hollman; Diane L Dahm
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-13       Impact factor: 4.342

2.  Is the all-arthroscopic tibial inlay double-bundle PCL reconstruction a viable option in multiligament knee injuries?

Authors:  Alexander E Weber; Benjamin Bissell; Edward M Wojtys; Jon K Sekiya
Journal:  Clin Orthop Relat Res       Date:  2014-09       Impact factor: 4.176

3.  Effect of tibial positioning on the diagnosis of posterolateral rotatory instability in the posterior cruciate ligament-deficient knee.

Authors:  Eric J Strauss; Charbel Ishak; Christopher Inzerillo; Michael Walsh; Gokce Yildirim; Peter Walker; Laith Jazrawi; Jeffrey Rosen
Journal:  Br J Sports Med       Date:  2007-01-29       Impact factor: 13.800

4.  Is triaxial accelerometer reliable in the evaluation and grading of knee pivot-shift phenomenon?

Authors:  M Berruto; F Uboldi; L Gala; B Marelli; W Albisetti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-08       Impact factor: 4.342

5.  The use of a robotic tibial rotation device and an electromagnetic tracking system to accurately reproduce the clinical dial test.

Authors:  S K Stinton; R Siebold; H Freedberg; C Jacobs; T P Branch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-18       Impact factor: 4.342

Review 6.  Current Concepts of Posterolateral Corner Injuries of the Knee.

Authors:  Oog-Jin Shon; Jae-Woo Park; Beum-Jung Kim
Journal:  Knee Surg Relat Res       Date:  2017-12-01

7.  Measurement of Knee Rotation Angles Using a Smartphone Application: An Experimental Study of Porcine Knees.

Authors:  Hee-June Kim; Hyun-Joo Lee; Ji-Yeon Shin; Young-Seo Choi; Hee-Soo Kyung
Journal:  Knee Surg Relat Res       Date:  2017-12-01

8.  The influence of tibial positioning on the diagnostic accuracy of combined posterior cruciate ligament and posterolateral rotatory instability of the knee.

Authors:  Young-Bok Jung; Chang-Hyun Nam; Ho-Joong Jung; Yong-Seuk Lee; Young-Bong Ko
Journal:  Clin Orthop Surg       Date:  2009-05-26

9.  Rotational knee laxity: reliability of a simple measurement device in vivo.

Authors:  Andrew G Tsai; Volker Musahl; Hanno Steckel; Kevin M Bell; Thore Zantop; James J Irrgang; Freddie H Fu
Journal:  BMC Musculoskelet Disord       Date:  2008-03-18       Impact factor: 2.362

10.  Rater agreement reliability of the dial test in the ACL-deficient knee.

Authors:  Malou E Slichter; Nienke Wolterbeek; K Gie Auw Yang; Jacco A C Zijl; Tom M Piscaer
Journal:  J Exp Orthop       Date:  2018-06-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.