Literature DB >> 9681230

Determination of leucocyte antibody binding capacity (ABC): the need for standardization.

D Barnett1, I Storie, G A Wilson, V Granger, J T Reilly.   

Abstract

The flow cytometric determination of antigen density, or cellular antibody binding capacity, is now an accepted technique for the characterization of cells in health and disease. In HIV infection, for example, antigen density changes in CD38 expression may be an important indicator of disease progression. Our experience of using one such method, Quantum Simply Cellular, which measures antibody binding capacity (ABC), has highlighted several technical factors which can affect the results. We report the influence of pH, incubation temperature and time, antibody fluorochrome and titre, as well as lysing reagent (FACS Lysing Solution v. Ortho-mune Lysing Reagent) on the ABC of anti-CD3, CD4 and CD8 of normal lymphocytes. In addition, the effect of single, double or triple-staining was assessed. The results indicate that the ABC values are influenced by all the variables studied. The pH range tested (6.0-9.0) demonstrated that pH 7.4 gave maximal binding. Furthermore, temperature also influenced the pH of the two lysing solutions, and thus potentially the ABC. Antibody concentration, fluorochrome and staining technique are also important factors with an observed difference of up to 458,855 ABC between the various fluorochromes. In addition a maximal difference of 130,119 ABC was observed between single and triple staining techniques. In conclusion, if antigen quantification is to be used in the clinical setting, an internationally standardized method is required to ensure the reproducibility of results from centre to centre. Our data suggests that single staining, using fluorescein isothiocynate (FITC) conjugated antibodies with all reagents at pH 7.4 + 0.1, with incubation and lysing carried out at 20 + 1 degrees C, could be used as a 'benchmark' method for ABC determination using the QSC system.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9681230     DOI: 10.1046/j.1365-2257.1998.00116.x

Source DB:  PubMed          Journal:  Clin Lab Haematol        ISSN: 0141-9854


  3 in total

1.  Variables affecting the quantitation of CD22 in neoplastic B cells.

Authors:  Gregory A Jasper; Indu Arun; David Venzon; Robert J Kreitman; Alan S Wayne; Constance M Yuan; Gerald E Marti; Maryalice Stetler-Stevenson
Journal:  Cytometry B Clin Cytom       Date:  2010-09-24       Impact factor: 3.058

2.  Consensus guidelines for myeloma minimal residual disease sample staining and data acquisition.

Authors:  Maryalice Stetler-Stevenson; Bruno Paiva; Lloyd Stoolman; Pei Lin; Jeffrey L Jorgensen; Alberto Orfao; Jacques Van Dongen; Andy C Rawstron
Journal:  Cytometry B Clin Cytom       Date:  2015-07-06       Impact factor: 3.058

3.  Erosion from Staphylococcus aureus biofilms grown under physiologically relevant fluid shear forces yields bacterial cells with reduced avidity to collagen.

Authors:  Patrick Ymele-Leki; Julia M Ross
Journal:  Appl Environ Microbiol       Date:  2007-02-02       Impact factor: 4.792

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.