Literature DB >> 9677078

Tibiotalocalcaneal arthrodesis: anatomic and technical considerations.

W C McGarvey1, S G Trevino, D E Baxter, P C Noble, L C Schon.   

Abstract

In the first of this two-part cadaver investigation, we inserted a specially designed, pointed device (simulating a 12-mm nail) in an antegrade fashion in each of eight fresh-frozen cadaver tibial specimens; the tibial isthmus was used as a centralizing guide. The exit point was noted, and the specimen was dissected to identify the structures at risk. In all specimens, we found that the device placed the lateral plantar artery and nerve at risk (average minimal distance from device to structure, 0 mm) and that damage to the flexor hallucis brevis and plantar fascia occurred. In addition, in six of the eight specimens, the device skewered or skived the flexor hallucis longus tendon. We also noted that in each specimen the exit point was the sustentaculum tali, not the body of the calcaneus as expected. Thus, there was less calcaneal bone-to-rod interface for stability, and distal locking would be less effective in the lateral-to-medial direction because of the lack of medial bone stock. On the basis of the results of the first portion of the study, we investigated an alternative approach to retrograde tibial nailing to reduce the risk of injury to the plantar and medial structures of the foot. We performed a medial malleolar resection, medially displaced the talus, inserted the device in an antegrade fashion, and dissected the specimens to analyze the structures at risk. We found that malleolar resection and medial translation of the distal extremity an average of 9.3 mm (range, 7-11 mm) increased the average minimal distance from the tip of the device to the neurovascular bundle to 18.4 mm (range, 14-32 mm). We also found that there was no damage to the flexor hallucis longus and that all eight specimens demonstrated bony contact completely surrounding the nail device within the tuberosity portion of the calcaneus (assessed by postoperative radiographs). The results of this study suggest that malleolar resection and medial translation of the distal extremity before retrograde nailing of the tibia may reduce the risk of vital structure injury and enhance the rigidity of the fixation.

Entities:  

Mesh:

Year:  1998        PMID: 9677078     DOI: 10.1177/107110079801900604

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  3 in total

1.  [Plantar approach to hindfoot arthrodesis with compressed angle stable locking option].

Authors:  T Mückley
Journal:  Unfallchirurg       Date:  2015-04       Impact factor: 1.000

2.  [Hindfoot fusion for Charcot osteoarthropathy with a curved retrograde nail].

Authors:  J Pyrc; A Fuchs; H Zwipp; S Rammelt
Journal:  Orthopade       Date:  2015-01       Impact factor: 1.087

3.  Novel Technique for Reduction of Ankle Valgus Malunion and Chronic Talus Subluxation during Hindfoot Nailing.

Authors:  Matthew Ciminero; Kevin Kang; Amr Abdelgawad
Journal:  Case Rep Orthop       Date:  2020-11-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.