Literature DB >> 9675174

A theoretical model study of the influence of fluid stresses on a cell adhering to a microchannel wall.

D P Gaver1, S M Kute.   

Abstract

We predict the amplification of mechanical stress, force, and torque on an adherent cell due to flow within a narrow microchannel. We model this system as a semicircular bulge on a microchannel wall, with pressure-driven flow. This two-dimensional model is solved computationally by the boundary element method. Algebraic expressions are developed by using forms suggested by lubrication theory that can be used simply and accurately to predict the fluid stress, force, and torque based upon the fluid viscosity, muoffhannel height, H, cell size, R, and flow rate per unit width, Q2-d. This study shows that even for the smallest cells (gamma = R/H << 1), the stress, force, and torque can be significantly greater than that predicted based on flow in a cell-free system. Increased flow resistance and fluid stress amplification occur with bigger cells (gamma > 0.25), because of constraints by the channel wall. In these cases we find that the shear stress amplification is proportional to Q2-d(1-gamma)-2, and the force and torque are proportional to Q2-d(1-gamma2)-5/2. Finally, we predict the fluid mechanical influence on three-dimensional immersed objects. These algebraic expressions have an accuracy of approximately 10% for flow in channels and thus are useful for the analysis of cells in flow chambers. For cell adhesion in tubes, the approximations are accurate to approximately 25% when gamma > 0.5. These calculations may thus be used to simply predict fluid mechanical interactions with cells in these constrained settings. Furthermore, the modeling approach may be useful in understanding more complex systems that include cell deformability and cell-cell interactions.

Mesh:

Year:  1998        PMID: 9675174      PMCID: PMC1299747          DOI: 10.1016/S0006-3495(98)77562-9

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  14 in total

1.  Chemotaxis of bacteria in glass capillary arrays. Escherichia coli, motility, microchannel plate, and light scattering.

Authors:  H C Berg; L Turner
Journal:  Biophys J       Date:  1990-10       Impact factor: 4.033

2.  Vascular endothelium-leukocyte interaction; sticking shear force in venules.

Authors:  G W Schmid-Schoenbein; Y C Fung; B W Zweifach
Journal:  Circ Res       Date:  1975-01       Impact factor: 17.367

3.  Bacterial migration along solid surfaces.

Authors:  G Harkes; J Dankert; J Feijen
Journal:  Appl Environ Microbiol       Date:  1992-05       Impact factor: 4.792

4.  Model studies of leukocyte-endothelium-blood interactions. I. The fluid flow drag force on the adherent leukocyte.

Authors:  G Chapman; G Cokelet
Journal:  Biorheology       Date:  1996 Mar-Apr       Impact factor: 1.875

5.  A microscale model of bacterial swimming, chemotaxis and substrate transport.

Authors:  R Dillon; L Fauci; D Gaver
Journal:  J Theor Biol       Date:  1995-12-21       Impact factor: 2.691

6.  Model studies of leukocyte-endothelium-blood interactions. II. Hemodynamic impact of leukocytes adherent to the wall of post-capillary vessels.

Authors:  G B Chapman; G R Cokelet
Journal:  Biorheology       Date:  1997 Jan-Feb       Impact factor: 1.875

Review 7.  Effects of fluid dynamic forces on vascular cell adhesion.

Authors:  K Konstantopoulos; L V McIntire
Journal:  J Clin Invest       Date:  1996-12-15       Impact factor: 14.808

Review 8.  Flow-mediated endothelial mechanotransduction.

Authors:  P F Davies
Journal:  Physiol Rev       Date:  1995-07       Impact factor: 37.312

9.  Subcellular distribution of shear stress at the surface of flow-aligned and nonaligned endothelial monolayers.

Authors:  K A Barbee; T Mundel; R Lal; P F Davies
Journal:  Am J Physiol       Date:  1995-04

10.  Morphometry of pulmonary veins in man.

Authors:  K Horsfield; W I Gordon
Journal:  Lung       Date:  1981       Impact factor: 2.584

View more
  49 in total

1.  Vascular endothelial cells minimize the total force on their nuclei.

Authors:  A L Hazel; T J Pedley
Journal:  Biophys J       Date:  2000-01       Impact factor: 4.033

2.  Red blood cells augment leukocyte rolling in a virtual blood vessel.

Authors:  Cristiano Migliorini; YueHong Qian; Hudong Chen; Edward B Brown; Rakesh K Jain; Lance L Munn
Journal:  Biophys J       Date:  2002-10       Impact factor: 4.033

3.  Pseudopod projection and cell spreading of passive leukocytes in response to fluid shear stress.

Authors:  Mark F Coughlin; Geert W Schmid-Schönbein
Journal:  Biophys J       Date:  2004-09       Impact factor: 4.033

Review 4.  Cellular stress failure in ventilator-injured lungs.

Authors:  Nicholas E Vlahakis; Rolf D Hubmayr
Journal:  Am J Respir Crit Care Med       Date:  2005-02-01       Impact factor: 21.405

5.  Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator.

Authors:  Glenn M Walker; Jiqing Sai; Ann Richmond; Mark Stremler; Chang Y Chung; John P Wikswo
Journal:  Lab Chip       Date:  2005-04-27       Impact factor: 6.799

6.  Micro-PTV measurement of the fluid shear stress acting on adherent leukocytes in vivo.

Authors:  John E Pickard; Klaus Ley
Journal:  Biophys J       Date:  2009-05-20       Impact factor: 4.033

7.  Biophysical determinants of alveolar epithelial plasma membrane wounding associated with mechanical ventilation.

Authors:  Omar Hussein; Bruce Walters; Randolph Stroetz; Paul Valencia; Deborah McCall; Rolf D Hubmayr
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2013-08-30       Impact factor: 5.464

8.  Critical stresses for cancer cell detachment in microchannels.

Authors:  Cécile Couzon; Alain Duperray; Claude Verdier
Journal:  Eur Biophys J       Date:  2009-07-05       Impact factor: 1.733

9.  Microcirculation within grooved substrates regulates cell positioning and cell docking inside microfluidic channels.

Authors:  Amir Manbachi; Shamit Shrivastava; Margherita Cioffi; Bong Geun Chung; Matteo Moretti; Utkan Demirci; Marjo Yliperttula; Ali Khademhosseini
Journal:  Lab Chip       Date:  2008-04-04       Impact factor: 6.799

10.  Recoil and stiffening by adherent leukocytes in response to fluid shear.

Authors:  Mark F Coughlin; David D Sohn; Geert W Schmid-Schönbein
Journal:  Biophys J       Date:  2007-10-05       Impact factor: 4.033

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.